Does Fibrin Glue Sealant Used During Pancreaticoduodenectomy Reduce Post-Operative Complication? Audit of 100 Consecutive Patients Undergoing Whipple’s Procedure by a Single Surgeon

نویسندگان

  • Shafiq Rehman
  • Bryon C Jaques
چکیده

Introduction This study evaluated the effect of fibrin glue applied as a sandwich film between a two layer pancreatico-jejunostomy anastomosis following pancreaticoduodenectomy. Primary end-points were post-operative pancreatic fistulae, overall complication rates and post-operative length of stay. Methods Pancreaticoduodenectomy was performed by fashioning a two layer pancreatico-jejunostomy with or without a glue sealant which when applied, formed a thin film external to the ductal anastomosis but internal to the seromuscularpancreatic parenchymal layer. Results Following audit of 100 consecutive patients undergoing pancreaticoduodenectomy, patients were separated into two groups; those with glue augmented anastomosis [Glue (G) N=50] or those without [No Glue (NG), N=50]. Each group was matched with regard to age [median, G=68 years vs. NG=66 years, (P=0.19)] and sex (P=0.84). There were no statistically significant differences between the two groups with respect to overall POPF [G N=7(14%) vs. NG N=11(22%), (P=0.42)], significant complications (Clavien Grade 3 or more), [G N=4(8%) vs. NG N=2(4%) (P=0.40)], or post-operative length of stay [G 13 days vs. NG 14 days, (P=0.90)]. In those patients with the highest fistulae risk score, there were significantly more post-operative pancreatic fistulae in the no glue cohort. There was no mortality in either group. Conclusion This study shows that application of sealant glue significantly reduces post-operative pancreatic fistulae in high-risk patients, but does not reduce overall complications or hospital stay following pancreaticoduodenectomy. Received October 01st, 2015 Accepted November 10th, 2015

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Short scar face-lift with the use of fibrin sealant.

Fibrin sealants have been used in surgical procedures for decades. This article focuses on the short scar face-lift and the applicability of Tisseel fibrin sealant, or "tissue glue," in expediting the healing process in a series of consecutive patients undergoing face-lift surgery. The evolution of the face-lift incision into the short scar and the adjunctive use of the Tisseel fibrin sealant h...

متن کامل

Application of fibrin sealant at the urethrovesical anastomosis in robotic assisted radical prostatectomy: does it enable earlier Foley catheter and Jackson–Pratt drain removal?

Leakage at the urethrovesical anastomosis in the post-operative period can result in morbidity including ileus. We examined the effectiveness of using a fibrin sealant at the anastomosis to limit urine leakage thereby facilitating earlier Jackson-Pratt drain and Foley catheter removal following robotic assisted laparoscopic prostatectomy (RALRP). Forty consecutive patients underwent RALRP by on...

متن کامل

The use of autologous platelet-rich plasma (platelet gel) and autologous platelet-poor plasma (fibrin glue) in cosmetic surgery.

The purpose of this study was to evaluate a new technique of harvesting and preparing autologous platelet gel and autologous fibrin glue (body glue) and to evaluate their effectiveness in stopping capillary bleeding in the surgical flaps of patients undergoing cosmetic surgery. A convenience sample of 20 patients ranging from 25 to 76 years of age undergoing cosmetic surgery involving the creat...

متن کامل

The appearance of dural sealants under MR imaging.

Dural sealants are an adjunct to obtain watertight closure after intradural procedures. This study aims to characterize the appearance on MR imaging of 3 commonly employed dural sealants: fibrin glue, PEGH, and BSAG. To this end, patients who underwent spinal intradural procedures that included the use of dural sealant during closure were identified retrospectively. Post-operative data on 15 pa...

متن کامل

A Cost-benefit Analysis of Using Polyethylene Glycol Hydrogel Sealant versus Fibrin Glue as a Dural Sealant for Posterior Fossa Surgery in the United States

Background: Cerebrospinal fluid (CSF) leaks are a well-known complication of posterior fossa neurosurgery. The use of dural repair adjuncts has been associated with fewer CSF leaks and subsequently, lower medical costs. Objectives: To determine if the use of polyethylene glycol hydrogel sealant (DuraSeal dural sealant system [DuraSeal]), resulted in cost savings in the United States compared to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -