BEAM HALO MONITOR USING DIAMOND DETECTOR FOR INTERLOCK SENSOR AT XFEL/SPring-8
نویسندگان
چکیده
An electron beam halo monitor has been developed in order to protect undulator permanent magnets against radiation damage for the X-ray free electron laser facility at SPring-8 (XFEL/SPring-8). The halo monitor will be installed at the upstream of the undulator and detect the electron beam that might hit the undulator magnets. Diamond detector, which operates in photoconductive mode, is good candidate for electron beam sensor, because diamond has excellent physical properties, such as, high radiation hardness, high insulation resistance and sufficient heat resistance. Pulse-by-pulse measurement suppresses the background noise efficiently, especially in the facilities having extremely high intense beam with low repetition rate, such as XFELs. The feasibility study of this monitor was performed at the SPring-8 compact SASE source (SCSS) test accelerator for XFEL/SPring-8. We observed the unipolar pulse signal with the pulse length of 0.4 nsec FWHM. The beam profiles of the halo can be also measured by scanning the sensor of this monitor.
منابع مشابه
Beam Halo Monitor Using Diamond Detectors for Xfel/spring-8
We have been developing an electron beam halo monitor as an interlock device for protection of undulator permanent magnets against radiation damage. When permanent magnets are irradiated with a halo part of 8GeV electron beam, magnetic fields undulators are degraded permanently and laser oscillation is weakened. Therefore, the interlock device is required during machine operation. Diamond detec...
متن کاملDESIGN OF THE ACCELERATOR SAFETY INTERLOCK SYSTEM FOR XFEL IN SPring-8
The accelerator safety interlock system (ASIS) for the X-ray free electron laser (XFEL) at SPring-8 protects personnel from radiation hazards. We developed an ASIS consisting of three interlock systems: a central interlock system (CIS), an emergency interlock system (EIS), and a beam route interlock system (BIS). The CIS and EIS monitor the safety equipment status and emergency stop buttons, re...
متن کاملElectron Beam Position Monitor (ebpm) Diagnostics for Diamond
This paper presents a global view of the proposed diagnostic systems for DIAMOND, but discusses in greatest detail the EBPMs, including data acquisition and control. Details of Total Current Monitor systems, and an active, beam position based interlock system for protecting ID vessels against thermal damage, by beam mis-steer, are also included.
متن کاملPulse-resolved intensity measurements at a hard X-ray FEL using semi-transparent diamond detectors.
Solid-state ionization chambers are presented based on thin diamond crystals that allow pulse-resolved intensity measurements at a hard X-ray free-electron laser (FEL), up to the 4.5 MHz repetition rate that will become available at the European XFEL. Due to the small X-ray absorption of diamond the thin detectors are semi-transparent which eases their use as non-invasive monitoring devices in ...
متن کاملDevelopment of Diamond Sensors for Beam Halo and Compton Spectrum Diagnostics after the Interaction Point of Atf2*
ATF2 is a low energy (1.3GeV) prototype of the final focus system for ILC and CLIC linear collider projects. A major issue at ATF2 and in linear colliders is to control the beam halo, which consists of tails extending far beyond the Gaussian core of the beam. At present there is no dedicated collimation for the beam halo at ATF2, and the transverse distribution near the interaction point is not...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -