Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on muscle force production in people with spinal cord injury (SCI)

نویسندگان

  • Vanesa Bochkezanian
  • Robert U Newton
  • Gabriel S Trajano
  • Amilton Vieira
  • Timothy S Pulverenti
  • Anthony J Blazevich
چکیده

BACKGROUND Neuromuscular electrical stimulation (NMES) is commonly used in skeletal muscles in people with spinal cord injury (SCI) with the aim of increasing muscle recruitment and thus muscle force production. NMES has been conventionally used in clinical practice as functional electrical stimulation (FES), using low levels of evoked force that cannot optimally stimulate muscular strength and mass improvements, and thus trigger musculoskeletal changes in paralysed muscles. The use of high intensity intermittent NMES training using wide-pulse width and moderate-intensity as a strength training tool could be a promising method to increase muscle force production in people with SCI. However, this type of protocol has not been clinically adopted because it may generate rapid muscle fatigue and thus prevent the performance of repeated high-intensity muscular contractions in paralysed muscles. Moreover, superimposing patellar tendon vibration onto the wide-pulse width NMES has been shown to elicit further increases in impulse or, at least, reduce the rate of fatigue in repeated contractions in able-bodied populations, but there is a lack of evidence to support this argument in people with SCI. METHODS Nine people with SCI received two NMES protocols with and without superimposing patellar tendon vibration on different days (i.e. STIM and STIM+vib), which consisted of repeated 30 Hz trains of 58 wide-pulse width (1000 μs) symmetric biphasic pulses (0.033-s inter-pulse interval; 2 s stimulation train; 2-s inter-train interval) being delivered to the dominant quadriceps femoris. Starting torque was 20% of maximal doublet-twitch torque and stimulations continued until torque declined to 50% of the starting torque. Total knee extensor impulse was calculated as the primary outcome variable. RESULTS Total knee extensor impulse increased in four subjects when patellar tendon vibration was imposed (59.2 ± 15.8%) but decreased in five subjects (- 31.3 ± 25.7%). However, there were no statistically significant differences between these sub-groups or between conditions when the data were pooled. CONCLUSIONS Based on the present results there is insufficient evidence to conclude that patellar tendon vibration provides a clear benefit to muscle force production or delays muscle fatigue during wide-pulse width, moderate-intensity NMES in people with SCI. TRIAL REGISTRATION ACTRN12618000022268 . Date: 11/01/2018. Retrospectively registered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on the decline and recovery of muscle force

BACKGROUND Neuromuscular electrical stimulation (NMES) is commonly used to activate skeletal muscles and reverse muscle atrophy in clinical populations. Clinical recommendations for NMES suggest the use of short pulse widths (100-200 μs) and low-to-moderate pulse frequencies (30-50 Hz). However, this type of NMES causes rapid muscle fatigue due to the (non-physiological) high stimulation intens...

متن کامل

Comparison of Agonist vs. Antagonist Stimulation on Triceps Surae Spasticity in Spinal Cord

Objectives: One of the most common and disabling complications that affects individuals with spinal cord injury is spasticity. The purpose of this study is to compare the effect of agonist and antagonist electrical stimulations on triceps surae muscle spasticity in patients with spinal cord injury. Methods: A total of 30 subjects with spinal cord injury were considered for the study. They were...

متن کامل

H-reflexes reduce fatigue of evoked contractions after spinal cord injury.

INTRODUCTION Neuromuscular electrical stimulation (NMES) over a muscle belly (mNMES) generates contractions predominantly through M-waves, while NMES over a nerve trunk (nNMES) can generate contractions through H-reflexes in people who are neurologically intact. We tested whether the differences between mNMES and nNMES are present in people with chronic motor-complete spinal cord injury and, if...

متن کامل

Alterations in body composition and spasticity following subtetanic neuromuscular electrical stimulation training in spinal cord injury.

The objective of this prospective cohort study was to investigate alterations in body composition variables and spasticity following subtetanic neuromuscular electrical stimulation (NMES) training in an adult population with spinal cord injury (SCI). Fourteen sedentary adults with SCI (thoracic [T]4-T11; American Spinal Injury Association Impairment Scale A/B; time since injury: 10.17 +/- 11.17...

متن کامل

Skeletal muscle hypertrophy and decreased intramuscular fat after unilateral resistance training in spinal cord injury: case report.

BACKGROUND Skeletal muscle atrophy is a common adaptation after spinal cord injury (SCI) that results in numerous health-related complications. Neuromuscular electrical stimulation (NMES) has been recognized as an effective tool, which attenuates atrophy and evokes hypertrophy. OBJECTIVE To investigate the effects of NMES resistance training (RT) on individual muscle groups and adipose tissue...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2018