Neuromagnetic source localization of auditory evoked fields and intracerebral evoked potentials: a comparison of data in the same patients.
نویسندگان
چکیده
OBJECTIVE To compare the localizations of different neural sources (a) obtained from intracerebral evoked responses and (b) calculated from surface auditory evoked field responses recorded in the same subjects. Our aim was to evaluate the resolving power of a source localization method currently used in our laboratory, which is based on a recent spatio-temporal algorithm used in magneto-encephalography (MEG). METHODS Auditory evoked responses were studied in 4 patients with medically intractable epilepsy. These responses were recorded from depth electrodes implanted in the auditory cortex for pre-surgical evaluation (stereo-electro-encephalography (SEEG)), as well as from surface captors (for MEG) placed on the scalp after removal of the depth electrodes. Auditory stimuli were clicks and short tone bursts with different frequencies. RESULTS All middle-latency components (from 13 to 70 ms post-stimulus onset) were recorded and localized (via SEEG) along Heschl's gyrus (HG). MEG reliably localized Pam and P1m in the same area of HG that intracerebral recordings localized them in. No significant delay between SEEG and MEG latencies was observed. Both methods suggest that N1 is generated from different sources in the intermediate and lateral parts of the HG and in the planum temporale (PT). The source of P2 (PT and/or Area 22) remains unclear and was in one case, localized in different regions according to the method used. This latter component may therefore also be generated by different sources. CONCLUSIONS The results suggest that both techniques are useful and may be used together in a complementary fashion. Intracerebral recordings allow the researcher to validate and interpret surface recordings.
منابع مشابه
Comparison of the extratympanic electrocochleography in human and rabbit
Electrocochleography (ECoG) records the electrophysiologic activity of the most peripheral part of the auditory system, the inner ear cochlea and the 8th nerve. Auditory evoked potentials being recorded are Cochlear Microphonic (CM) and Summating Potential (AP). In order to provide the proper background for laboratory research and introducing an ECoG curve of a model animal, it was decided to...
متن کاملفراوانی پتانسیلهای برانگیخته غیر طبیعی در مالتیپل اسکلروزیس: مطالعه مقطعی در 25 بیمار
Background: Visual, brain stem auditory and somatosensory evoked potentials (EPs) have been traditional paraclinical tests to evaluate the competency of sensory tracts in multiple sclerosis (MS) patients. It seems that only one of these EPs could be sufficient, at least as a screening test. The objective of this paper is to evaluate the frequency of these three evoked potentials in definite MS ...
متن کاملEvaluation of Distortion and Transient Evoked Otoacoustic Emission in Tinnitus Patients with Normal Hearing
Introduction: Tinnitus is a perception of sound without external source. The exact etiology of tinnitus is not fully understood, although some researchers believe that the condition usually starts in the cochlea. The aim of this study was to determine the potential contribution of outer hair cell dysfunction to chronic tinnitus, by application of Distortion-Product Evoked Otoacoustic Emission (...
متن کاملCervical and ocular vestibular evoked myogenic potentials in multiple sclerosis participants
Background: Multiple sclerosis (MS) is a chronic neurological disease that affects brain and spinal cord. The infratentorial region contains the cerebellum and brainstem. Vestibular evoked myogenic potentials (VEMPs) are short-latency myogenic responses. Cervical vestibular evoked myogenic potential (cVEMP) is a manifestation of vestibulocolic reflex and ocular vestibular evoked myogenic pote...
متن کاملMachine learning based Visual Evoked Potential (VEP) Signals Recognition
Introduction: Visual evoked potentials contain certain diagnostic information which have proved to be of importance in the visual systems functional integrity. Due to substantial decrease of amplitude in extra macular stimulation in commonly used pattern VEPs, differentiating normal and abnormal signals can prove to be quite an obstacle. Due to developments of use of machine l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology
دوره 112 10 شماره
صفحات -
تاریخ انتشار 2001