Ghost artifact reduction for echo planar imaging using image phase correction.

نویسندگان

  • M H Buonocore
  • L Gao
چکیده

An algorithm is described for reducing ghost artifacts in echo planar imaging (EPI) using phase corrections derived from images reconstructed using only even or odd k-space lines. The N/2 ghost, that arises principally from time-reversal of alternate k-space lines, was significantly reduced by this algorithm without the need for a calibration scan. In images obtained in eight subjects undergoing EPI for auditory functional MRI (fMRI) experiments, N/2 ghost intensity was reduced from 10.3% +/- 2.1% (range: 7.9-14.1%) to 4.5% +/- 0.2% (range: 4.1-4.9%) of parent image intensity, corresponding to a percent reduction in ghost intensity of 54% +/- 9% (range: 43-65%), and the algorithm restored this intensity to the parent image. It provided a significant improvement in image appearance, and increased the correlation coefficients related to neural activation in functional MRI studies. The algorithm provided reduction of artifacts from all polynomial orders of spatial phase errors in both spatial directions. The algorithm did not eliminate N/2 ghost intensity contributed by field inhomogeneities, susceptibility, or chemical shift.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Robust 2D phase correction for echo planar imaging under a tight field-of-view.

Nyquist ghost artifacts are a serious issue in echo planar imaging. These artifacts primarily originate from phase difference between even and odd echo images and can be removed or reduced using phase correction methods. The commonly used 1D phase correction can only correct phase difference along readout axis. 2D correction is, therefore, necessary when phase difference presents along both rea...

متن کامل

High spatial resolution EPI using an odd number of interleaves.

Ghost artifacts in echoplanar imaging (EPI) arise from phase errors caused by differences in eddy currents and gradient ramping during left-to-right traversal of kx(forward echo) versus right-to-left traversal of kx (reverse echo). Reference scans do not always reduce the artifact and may make image quality worse. To eliminate the need for reference scans, a ghost artifact reduction technique b...

متن کامل

Robust EPI Nyquist ghost elimination via spatial and temporal encoding.

Nyquist ghosts are an inherent artifact in echo planar imaging acquisitions. An approach to robustly eliminate Nyquist ghosts is presented that integrates two previous Nyquist ghost correction techniques: temporal domain encoding (phase labeling for additional coordinate encoding: PLACE and spatial domain encoding (phased array ghost elimination: PAGE). Temporal encoding modulates the echo plan...

متن کامل

Reference-free single-pass EPI Nyquist ghost correction using annihilating filter-based low rank Hankel matrix (ALOHA).

PURPOSE MR measurements from an echo-planar imaging (EPI) sequence produce Nyquist ghost artifacts that originate from inconsistencies between odd and even echoes. Several reconstruction algorithms have been proposed to reduce such artifacts, but most of these methods require either additional reference scans or multipass EPI acquisition. This article proposes a novel and accurate single-pass E...

متن کامل

Single-Shot and Segmented EPI Ghost Artifacts Removal with Two-Dimensional Phase Correction

Introduction Asymmetry between odd and even echoes generates Nyquist ghost artifact in a single-shot EPI , and further enhances multiple ghost artifacts in a segmented EPI. These ghost artifacts not only severely degrade EPI image quality, but may lead to incorrect ADC values in EPI based diffusion measurements (1). Methods currently available for odd-even-echo asymmetry compensation include on...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 38 1  شماره 

صفحات  -

تاریخ انتشار 1997