Biomechanical evaluation of the elbow using roentgen stereophotogrammetric analysis.

نویسندگان

  • Denise Eygendaal
  • Edward R Valstar
  • Jens O Söjbjerg
  • Piet M Rozing
چکیده

The medial collateral ligament complex is the primary constraint of the elbow to valgus forces and is composed of the anterior bundle, the posterior bundle, and a transverse part. Total and partial ruptures have been described. Clinical and radiologic examinations of medial or valgus instability of the elbow are difficult. The effect of different stages of medial collateral ligament ruptures on ulnohumeral movement in cadavers was determined to rationalize the use of physical and radiologic examinations in different stages of valgus instability in vivo. Using roentgen stereophotogrammetric analysis, motion is determined between the humerus and ulna under valgus load and between the humerus and radius during maximal pronation of the forearm after various dimensions of medial collateral ligament lesions. The increase in distance between the humerus and ulna under a 15 N valgus load varied from 2.7 mm to 9.8 mm. The increase in distance between the humerus and proximal radius with the forearm in pronation in an intact specimen and after transsection of the anterior medial collateral ligament and posterior medial collateral ligament in the anterior direction was 9.7 mm. These results suggest that detection of partial ruptures with clinical and radiologic examinations is difficult. Anterior movement of the radial head can be used as an additional parameter of valgus instability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Digital Roentgen Stereophotogrammetry : Development , Validation , and Clinical Application

Contents 1 General introduction 9 2 RSA in practical steps 19 3 RSA of the Mallory-Head femoral stem without attached markers 33 4 Roentgen stereophotogrammetric analysis of metal-backed hemispherical cups without attached markers 49 5 Fast and accurate automated measurements in digitised stereophotogrammetric radiographs 59 6 Digital automated RSA compared to manually operated RSA 75 7 Model-b...

متن کامل

Migration of the humeral component of the Souter-Strathclyde elbow prosthesis: a long-term RSA study.

Mechanical loosening which begins with early-onset migration of the prosthesis is the major reason for failure of the Souter-Strathclyde elbow replacement. In a prospective study of 18 Souter-Strathclyde replacements we evaluated the patterns of migration using roentgen stereophotogrammetric analysis. We had previously reported the short-term results after a follow-up of two years which we have...

متن کامل

Re: the premature failure of the Charnley Elite-Plus stem: a confirmation of RSA predictions.

We performed a clinical and radiological study to determine the rate of failure of the Charnley Elite-Plus femoral component. Our aim was to confirm or refute the predictions of a previous roentgen stereophotogrammetric analysis study in which 20% of the Charnley Elite-Plus stems had shown rapid posterior head migration. It was predicted that this device would have a high early rate of failure....

متن کامل

Manipulation does not alter the position of the sacroiliac joint. A roentgen stereophotogrammetric analysis.

STUDY DESIGN A roentgen stereophotogrammetric analysis study of patients with sacroiliac joint dysfunction. OBJECTIVES To investigate whether manipulation can influence the position between the ilium and the sacrum, and whether positional tests for the sacroiliac joint are valid. SUMMARY OF BACKGROUND DATA Sacroiliac joint dysfunction is a subject of controversy. The validity of different s...

متن کامل

Validation of a new method for finding the rotational axes of the knee using both marker-based roentgen stereophotogrammetric analysis and 3D video-based motion analysis for kinematic measurements.

In a previous paper, we reported the virtual axis finder, which is a new method for finding the rotational axes of the knee. The virtual axis finder was validated through simulations that were subject to limitations. Hence, the objective of the present study was to perform a mechanical validation with two measurement modalities: 3D video-based motion analysis and marker-based roentgen stereopho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical orthopaedics and related research

دوره 396  شماره 

صفحات  -

تاریخ انتشار 2002