Double-crowned valved stents for off-pump mitral valve replacement.
نویسندگان
چکیده
OBJECTIVE An animal model has been designed to assess the feasibility of off-pump mitral valve replacement using valved stents. METHODS Glutaraldehyde-preserved homograft was sutured inside a prosthetic tube (Dacron). Then, two self-expandable nitinol Z-stents were sutured on the external surface of the prosthesis in such a way to create two self-expanding crowns for fixation. In adult pigs and under general anesthesia, the left atrium was exposed through a left thoracotomy and atrio-ventricular roadmapping was performed with intravascular ultrasound (IVUS) and fluoroscopy. The double-crowned valved stents were loaded into a delivery sheath. The sheath was then introduced into the left atrium and the valved stents was deployed in mitral position in such a way that the part in between the two stents was at the level of the mitral annulus. Intracardiac Unltrasound (ICUS) was used to assess the valve function. Hemodynamic parameters were gathered as well. Animal survived for no more than 3h after the valve deployment and gross anatomy examination of the left heart was carried out. RESULTS The mean height of the valved stents was 29.4+/-0.2 mm, with an internal diameter of 20.4+/-1.0mm, and an external diameter of 25.5+/-0.8 mm. The procedure was successfully carried out in eight animals. In vivo evaluation showed a native mitral annulus diameter of 24.9+/-0.6 mm, and a mean mitral valve area of 421.4+/-17.5 mm2. ICUS showed a mild mitral regurgitation in three out of eight animals. Mean pressure gradient across the valved stents was 2.6+/-3.1 mmHg. Mean pressure gradient across the left ventricular outflow tract (LVOT) was 6.6+/-5.2 mmHg. The mean survival time was 97.5+/-56.3 min (survival time range was 40-180 min). One animal died due to the occlusion of the LVOT because of valved stents displacement. Postmortem evaluation confirmed correct positioning of the valved stent in the mitral position in seven out of eight animals. No atrial or ventricular lesions due to the valved stents were found. CONCLUSIONS Off-pump implantation of a self-expandable valved stent in the mitral position is technically feasible. Further studies will assess if this procedure is also feasible in humans.
منابع مشابه
Double Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.
Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. ...
متن کاملHigh-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient
Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...
متن کاملTransapical mitral valve implantation: the Lutter valve
The development of transcatheter techniques for treatment of severe mitral valve regurgitation in the beating heart is focus of recent research. An off-pump treatment technique poses great benefits, particularly for multimorbid patients, often being non-compliant to the gold standard treatment, being open heart surgery with use of a cardiopulmonary bypass. Thereto, two approaches are being fo...
متن کاملPercutaneous pulmonary valve replacement: autologous tissue-engineered valved stents.
AIMS Percutaneous implantation has already been used clinically and is a great option for treating young patients. The use of autologous tissue-engineered valved stents might solve the problem of degeneration and limited durability of biological heart valves. METHODS AND RESULTS Porcine pulmonary heart valves and small intestinal submucosa were obtained from a slaughterhouse. The intestinal s...
متن کاملSteps toward percutaneous aortic valve replacement.
BACKGROUND To date, the surgical approach is the only option to replace the aortic valve. Percutaneous pulmonary valve replacement has recently opened new perspectives on transcatheter replacement of cardiac valves. We report our experience of aortic valve replacement through a percutaneous technique in lambs. METHODS AND RESULTS A bovine jugular vein containing a valve was dissected and sutu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 28 2 شماره
صفحات -
تاریخ انتشار 2005