The early plasma concentration of 51Cr-EDTA in patients with cirrhosis and ascites: a comparison of three models

نویسندگان

  • Surajith N. Wanasundara
  • Michal J. Wesolowski
  • Richard C. Puetter
  • Maria T. Burniston
  • Elias Xirouchakis
  • Ioannis G. Giamalis
  • Paul S. Babyn
  • Carl A. Wesolowski
چکیده

OBJECTIVES The aim of the study was to determine which of three two-parameter fitting functions (exponential, linear-log, and negative-power function of time) most accurately models early chromium-51-EDTA (51Cr-EDTA) plasma concentration data prior to 120 min in patients with cirrhosis and ascites and understand how these fitting functions affect the calculation of the area under the plasma concentration curve (AUC). METHODS A bolus, antecubital intravenous injection of 2.6 MBq of 51Cr-EDTA was given to 13 patients with cirrhosis and ascites. Up to 16 blood samples were drawn at time points ranging from 5 to 1440 min following injection. The concentration data prior to 120 min were used as reference data. Early time concentration values, estimated by fitting exponential, linear-log, and negative-power functions of time to the time samples at 120, 180, and 240 min, were then compared with reference data. The AUC was calculated for each patient using the exponential, Bröchner-Mortensen-corrected exponential, and linear-log functions, and these values were compared. RESULTS The withheld, observed plasma concentrations were (a) most accurately estimated by linear-log functions (Wilcoxon P=0.4548), (b) significantly underestimated by exponential functions (Wilcoxon P=0.0002), and (c) significantly overestimated by negative-power functions (Wilcoxon P=0.0034). The relative errors when ranked from best to worst were those for the linear-log (12.0%, 9.0%), exponential (22.9%, 14.2%), and negative-power (31.9%, 48.4%) functions of time, respectively (median, interquartile range). For each patient, the values for AUC calculated by the exponential function differed significantly (range=3.4-15.3%, median=8.3%) from those calculated by the corrected Bröchner-Mortensen exponential, as to a lesser extent did those values calculated using linear-log functions (range=0.4-8.0%, median=3.0%). CONCLUSION In patients with cirrhosis, linear-log functions were significantly more accurate than exponential or power functions in estimating early time plasma concentrations (<120 min). However, the improved linear-log early time plasma concentration model does not provide as much correction to the total AUC as does the corrected Bröchner-Mortensen exponential method. This is likely because of the large contribution of late time data to the AUC, and future work is suggested to explore the late time fit problem.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی سطوح پلاسمایی محصولات تخریب فیبرینوژنFDP)) وD-dimer در بیماران سیروتیک با و بدون آسیت و ارتباط آن‌ها باMELD-score

    Received: 16 Oct, 2012 Accepted: 22 Dec, 2012      Background & Aims : Liver cirrhosis is associated with coagulation disorders due to decreased synthesis of clotting and inhibitor factors. It has been hypothesized that ascites plays an important role in hyperfibrinolytic state and increased risk of bleeding. We have studied the role of ascites in the hyper fibrinolytic state and relationsh...

متن کامل

بررسی یافته های اکوکاردیو گرافیک قلبی در بیماران سیروز کبدی

Introduction: Cardiovascular abnormalities have been reported in liver cirrhosis (LC). In these patients, cardiac symptoms and physical signs occur as the liver functions worsen. Cirrhosis is associated with hyper dynamic circulation and beta-adrenergic system changes responsible for the cardiovascular abnormalities. The purpose of the present study was to explore the echocardiographic findi...

متن کامل

Effect of early cold exposure on the endocrine responses of broiler chickens and the incidence of ascites syndrome.

Two hundred and fifty day-old broiler chickens were housed in a high altitude farm and divided in two experimental groups (cold-exposed and control). At the age of 3 and 4 d, the cold-exposed chickens were exposed to 15?C for 3 h, while the control birds were reared under normal condition. During the period between 14 and 28 days, both groups of chickens were exposed to a low environmental temp...

متن کامل

GFR measurement with iohexol and 51Cr-EDTA. A comparison of the two favoured GFR markers in Europe.

BACKGROUND The aim of the present study was to compare the most commonly used GFR markers for clearance measurements, 51Cr-EDTA and iohexol, using two different methods for iohexol analysis, HPLC and X-ray fluorescence, referring both to the multiple-sample and single-sample calculations, using 51Cr-EDTA as the reference method. METHODS Forty-nine patients with an estimated GFR >40 ml/min wer...

متن کامل

Simultaneous measurement of renal clearance and plasma clearance of 99mTc-labelled diethylenetriaminepenta-acetate, 51Cr-labelled ethylenediaminetetra-acetate and inulin in man.

The present investigation was undertaken to study the kinetics of 99mTc-labelled diethylenetriaminepenta-acetate (DTPA) as compared with inulin and 51Cr-labelled ethylenediaminetetra-acetate (EDTA). Twenty patients with various degrees of decreased renal function were studied. The renal clearance, plasma clearance and volume of distribution of all three tracers were measured after a simultaneou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 36  شماره 

صفحات  -

تاریخ انتشار 2015