Fully automated liquid-chromatographic determination of amino acids.

نویسندگان

  • H M van Eijk
  • M A van der Heijden
  • C L van Berlo
  • P B Soeters
چکیده

This inexpensive method for fully automated amino acid analysis combines the advantages of automated precolumn derivatization with o-phthaldialdehyde and favorable analytical conditions to separate and quantify 30 amino acids found in normal plasma. The system can run unattended for almost four days, during which the data are processed automatically by a personal computer and a maximum of 76 samples and 19 standards can be processed (cycle time per analysis: 55 min). Only 1 microL of deproteinized plasma is required per analysis. Coefficients of variation for retention times and areas measured for all relevant amino acids are less than 1% and 3%, respectively. The system described is well suited for quick, sensitive operation in daily practice.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC ANALYSIS OF SULFUR MUSTARD REACTION WITH AMINO ACIDS AND PROTEINS

The interaction of sulfur mustard with aminoacids and proteins has been investigated in this study. Rats were injected with sublethal doses of sulfur mustard subcutaneously and intraperitoneally. At different time intervals, plasma and urine samples were collected. The binding affinity of sulfur mustard with urinary and plasma proteins and enzymes was studied for the first time using non-i...

متن کامل

Coupling of sequential injection with liquid chromatography for the automated derivatization and on-line determination of amino acids.

The principle of sequential injection (SI) was exploited to develop a fully automated pre-column derivatization procedure combined on-line to liquid chromatography (LC). Using SI-LC derivatization 14 amino acids were determined fluorimetrically in pharmaceuticals with o-phthaldialdehyde (OPA) as the derivatization reagent. The SI system was used for the handling of samples and reagents, on-line...

متن کامل

HPLC-FLD for the simultaneous determination of primary and secondary amino acids from complex biological sample by pre-column derivatization.

A rapid, sensitive, and reproducible pre-column derivatisation procedure has been established for the simultaneous determination of 20 amino acids by high-performance liquid chromatography using fluorescence detection. The amino acids were derivatized using o-phthalaldehyde and 9-fluorenylmethyl-chloroformate reagents. The optimal conditions for simultaneous separation and detection of both pri...

متن کامل

Analysis of Plasma Amino Acids Using RP-HPLC and Pre-Column Derivatization with OPA/3-MPA

ABSTRACT        Background and Objective: Measurement of amino acids is an important tool for metabolic studies and evaluation of patients’ clinical condition. The aim of this study was to analyze the plasma amino acids using reverse phase high performance liquid chromatography techniques (RP-HPLC) with pre-column derivatization by o-phthalaldehyde (OPA)...

متن کامل

Review: State-of-the-art of high-performance liquid chromatographic analysis of amino acids in physiological samples

Nowadays, the fast and sensitive high-performance liquid chromatographic I HPLC) analysis of derivatized amino acids is a good alternative to the ion-exchange chromatography (IEC) method for plasma amino acids. However, several precautions have to be taken in order to obtain reliable data on the concentration of amino acids in physiological fluids. These include the collection, centrifugation, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 34 12  شماره 

صفحات  -