Life-threatening anaphylactic shock caused by porcine heparin intravenous infusion during mitral valve repair.
نویسندگان
چکیده
ing or cannulation of the ascending aorta bear a stroke risk of more than 8% in octogenarians and may have been the cause for emboli. However, we cannot rule out that air provided by the blower mister device entered the aorta through a leak between the proximal seal and the aortic wall and caused the emboli. The possibility of such a mechanism was proven in an animal experiment. This should be sufficient reason to strongly discourage the simultaneous use of the HEARTSTRING device in combination with a blower mister. References
منابع مشابه
Clindamycin-induced anaphylactic shock during general anesthesia.
Clindamycin-related anaphylactic reaction is rarely reported. We report a male patient with buccal cancer who was undergoing radical neck dissection when life-threatening anaphylactic shock developed soon after intravenous infusion of clindamycin. Immediate cardiopulmonary resuscitation was performed, and the patient recovered uneventfully. Perioperative anaphylactic shock is a serious problem ...
متن کاملHeparin Resistance During and Post-Intravenous Nitroglycerin Infusion
Nitroglycerin has been reported to reduce activated partial thromboplastin time (aPTT) values in patients treated with concurrent heparin and nitroglycerin. However, studies have yielded conflicting results. To determine whether intravenous nitroglycerin alters the anticoagulant effect of heparin, we prospectively evaluated twenty patients admitted for coronary angioplasty by measurin...
متن کاملManagement of anticoagulant therapy during pregnancy in patients with prosthetic heart valves.
We describe two patients with Starr-Edwards mitral valve replacements who underwent pregnancy on oral anticoagulants and who were successfully delivered of live babies. The literature on pregnancy with prosthetic heart valves is reviewed. It is suggested that properly controlled oral anticoagulation should be continued until the onset of labour; the anticoagulant effect should then be reversed ...
متن کاملRecombinant tissue type plasminogen activator treatment of thrombosed mitral valve prosthesis during pregnancy.
PURPOSE Prosthetic heart valve thrombosis occurring during pregnancy is a life-threatening complication. Surgical treatment requires clot removal under cardiopulmonary bypass (CPB) and carries a high mortality. We describe the successful use of thrombolytic therapy for recurrent thrombosed valve prosthesis in a pregnant patient. CLINICAL FEATURES A 32-yr-old patient whose pregnancy was compli...
متن کاملLife-threatening anaphylactic shock due to chlorhexidine on the central venous catheter: a case series.
In this article, we report two life-threatening anaphylactic shocks by an antiseptic coated central venous catheter (CVC) within a 6-month period in our cancer center. Anaphylactic shock was preceded immediately after insertion of a central venous catheter (CVC) coated with silver sulphadiazine and chlorhexidine acetate (Blue FlexTip(®) ARROWg(+)ard Blue(®), 14Ga, Arrow International, Inc. USA)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of thoracic and cardiovascular surgery
دوره 126 4 شماره
صفحات -
تاریخ انتشار 2003