Simulated frame-loss artifacts in myocardial perfusion SPECT imaging: the difference between single- and dual-headed systems.
نویسنده
چکیده
OBJECTIVE Right-angle dual-headed tomography has increased cardiac SPECT utility by cutting acquisition time in half which enhances gating capabilities. When gating, however, a deceleration in heart rate, due to a return to baseline rate after stress or lessened anxiety at the end of a study, may significantly affect the last step(s) of a gated study with possible frame or information loss. The purpose of this study was to illustrate the artifacts produced in myocardial perfusion studies when a frame or frames are lost in single- and dual-detector SPECT imaging methodologies. METHODS A near-normal 99mTc-sestamibi study was obtained using a dual-headed camera system fitted with high-resolution, long-bore collimators. The normal study was processed including all frames (1-32). To demonstrate the effect of losing frames on a dual-headed system, the study was processed three different ways to simulate frame loss. RESULTS Loss of frames at the end of a SPECT acquisition results in significant inferoseptal wall defects, left ventricular lumen narrowing, as well as thinning of the anterior and lateral walls. The overall appearance of the heart is a more oval-shaped heart with decreased perfusion. The effect of losing the last frame in a dual-headed camera system as opposed to losing the last frame in a single-headed camera system is more substantial. CONCLUSION A scan resulting in the loss of a frame in either a single- or a dual-headed camera system creates artifacts in the myocardial wall and should always be repeated. It is significant to note that artifacts present in a dual-headed system are much more prevalent than in a single-headed system due to the nature of dual-headed acquisition parameters.
منابع مشابه
Assessment of simulated patient motion and its effect on myocardial perfusion SPECT using two reconstruction methods (Filtered Backprojection;FBP and Iterative method) [Persian]
Introduction: Motion of the patient during myocardial perfusion SPECT could potentially results in false perfusion defects. The effect of different reconstruction methods on these artifacts is not studied. Clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. This...
متن کاملDifferential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms
Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...
متن کاملAttenuation correction in myocardial perfusion SPECT using sequential transmission - emission scanning with 99mTc [Persain]
Introduction: Nowadays, Imaging of the myocardial perfusion (MPI) using the single photon emission tomography (SPET) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. In contrast to the coronary artery angiography, MPI is non-invasive, less expensive and more physiological. Unfortunately, this image is affected by the some artifacts. Thes...
متن کاملThe truncation artifact in a skinny patient following myocardial perfusion SPECT
Myocardial perfusion SPECT is one of the most common imaging techniques performed in nuclear medicine departments. To avoid misleading interpretation, it is necessary to address the quality control and technical problems. The truncation artifact occurs when the patient size is large relative to the field of view of the camera, causing false perfusion defects in the LV myocardium, misinterpreted...
متن کاملBenefits of combined pharmacologic and submaximal exercise stress on Sub-diaphragmatic activity in myocardial perfusion scintigraphy
Introduction: Myocardial perfusion imaging (MPI) is an important imaging modality in managing patients with cardiovascular disease. MPI has a significant role in diagnosis and management of cardiovascular disease; however it is subjected to different artifacts. Combining pharmacologic stress with submaximal exercise reduces side effects, improves image quality, and enhances the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine technology
دوره 26 4 شماره
صفحات -
تاریخ انتشار 1998