Nitinol flexigrip sternal closure system and chest wound infections: insight from a comparative analysis of complications and costs.
نویسندگان
چکیده
BACKGROUND We sought to assess the efficiency of two different sternal closure techniques in preventing sternal wound complications (SWC). A cost analysis was also considered. METHODS Between January 2008 and April 2010, 1,644 consecutive cardiac surgery patients who underwent cardiac surgery in our institute were prospectively collected. A total of 1,072 patients received a standard parasternal wiring technique (group A), and 572 patients received a new method of sternal closure based on the use of thermoreactive nitillium clips (Flexigrip; Praesidia SRL, Bologna, Italy [group B]). We investigated, by a propensity matched analysis, whether the use of standard or nitinol clip closure would impact on sternal wound outcome. RESULTS In all, 464 patients of each group were matched for 17 available risk factors. Overall incidence of SWC was significantly higher in group A (4.1% versus 1.7%; p=0.03). Sternal surgical revision to treat a thoracic instability was required in a significantly higher number of patients in group A (9 patients, 1.9%) and in none of group B (p=0.004). The incidence of sternal instability, secondary to wound infection, was significantly lower in group B (p=0.05). Overall costs were €7,407,296 and €6,896,432 in group A and group B, respectively. Thus, nitinol clip closure technique offered a €510,864 cost saving compared with standard steel wiring technique. CONCLUSIONS The Flexigrip assured a lower incidence of SWC. The use of the nitinol clip favored an improved sternal closure technique preventing mediastinitis. Additionally, the nitinol clip system proved to be cost effective in cardiac surgery.
منابع مشابه
Nitinol flexigrip sternal closure system and standard sternal steel wiring: insight from a matched comparative analysis.
OBJECTIVE We sought to assess the efficiency of two different sternal closure techniques in preventing sternal wound instability in high-risk patients. MATERIALS AND METHODS Between January 2009 and February 2012, 2068 consecutive cardiac patients were prospectively collected in our database. The 561 patients in whom the thermoreactive nitilium clips (Flexigrip) have been used (group A) were ...
متن کاملThe use of Nitinol clips for primary sternal closure in cardiac surgery.
PURPOSE Deep sternal wound complications after cardiac surgery have an incidence of 2 to 8% and carry a significant mortality. The aim of this study was to evaluate the effect of thermo-reactive Nitinol clips on the incidence of postoperative deep sternal wound complications. METHODS We retrospectively reviewed 1119 consecutive patients that underwent major cardiac surgery via median sternoto...
متن کاملImproved results of the vacuum assisted closure and Nitinol clips sternal closure after postoperative deep sternal wound infection.
OBJECTIVE Postoperative deep sternal wound infection is a severe complication of cardiac surgery, with a high mortality rate and a high morbidity rate. The objective of this prospective study is to report our experience with the vacuum assisted closure (VAC) system for the management of deep wound infection. We also devised an innovative closure technique post VAC therapy using thermo reactive ...
متن کاملA prospective randomized study of sternal closure: comparison of Mersilene tape versus standard wire closure.
BACKGROUND To compare in a prospective randomized study Mersilene tape and standard metal wire for complications and pain upon sternal wound closure. METHODS Sixty-four patients scheduled for cardiac surgery were prospectively randomized to undergo sternal closure using either Mersilene tape (n=30) or standard metal wire (n=34). The intensity of postoperative pain from the chest wound was ass...
متن کاملEvaluation of autologous platelet rich plasma for cardiac surgery: outcome analysis of 2000 patients
BACKGROUND Deep and superficial sternal wound infections (DSWI & SWI) following cardiac surgery increase morbidity, mortality and cost. Autologous platelet rich plasma (PRP) derived from the patient's own blood has been used in other surgical settings to promote successful wound healing. The goal of this study was to analyze the addition of PRP using a rapid point of care bedside system to stan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Annals of thoracic surgery
دوره 94 6 شماره
صفحات -
تاریخ انتشار 2012