Active Imaging with Dual Spin-Echo Diffusion MRI
نویسندگان
چکیده
Active imaging is a recently developed approach to model-based optimisation of imaging protocols. In the application we discuss here, a diffusion magnetic resonance imaging (dMRI) protocol is optimised for directly measuring aspects of biological tissue microstructure, subject to appropriate scanner hardware and acquisition time constraints. We present the theoretical basis for active imaging with the dual spin-echo (DSE) dMRI pulse sequence, which is more complex than the standard sequence, but widely used due to its robustness to image distortion. The new formulation provides the basis for future active imaging studies using DSE. To demonstrate the approach, we optimise DSE sequences for estimating parameters in a simple model of neural white matter, specifically axon density and diameter. Results show that sensitivity to these important parameters is at least as good as with more traditional pulse sequences that are not robust to image distortion.
منابع مشابه
Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کامل3D MRI gel dosimetry based on image intensity (A new approach)
Background: Since 1984 MRI gel dosimetry has been introduced as a potential technique for 3D dosimetry. Most of the studies have measured R1 (1/T1) or R2 (1/T2) properties of the gel depending on the gel type. We have studied image intensity change in the Fricke gel by different MRI protocols. Materials and Methods: Gel Dosimeters contain 0.4 mM ferrous sulphate, 1 mM NaCl, 50 mM H2SO4 and 1% b...
متن کاملاندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی
Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...
متن کاملMapping axon radius in the human corpus callosum using dual spin-echo diffusion MRI
Mapping axon radius in the human corpus callosum using dual spin-echo diffusion MRI Jonathan D Clayden, Zoltan Nagy, Nikolaus Weiskopf, Daniel C Alexander, and Chris A Clark Institute of Child Health, University College London, London, United Kingdom, Wellcome Trust Centre for Neuroimaging, University College London, London, United Kingdom, Centre for Medical Image Computing, University College...
متن کاملDiffusion-prepared fast imaging with steady-state free precession (DP-FISP): a rapid diffusion MRI technique at 7 T.
Diffusion MRI is a useful imaging technique with many clinical applications. Many diffusion MRI studies have utilized echo-planar imaging (EPI) acquisition techniques. In this study, we have developed a rapid diffusion-prepared fast imaging with steady-state free precession MRI acquisition for a preclinical 7T scanner providing diffusion-weighted images in less than 500 ms and diffusion tensor ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Information processing in medical imaging : proceedings of the ... conference
دوره 21 شماره
صفحات -
تاریخ انتشار 2009