Effect of sport-tinted contact lenses for contrast enhancement on retinal straylight measurements.
نویسندگان
چکیده
PURPOSE To investigate the effect of two tinted contact lenses (CL) designed for outdoor sports activity on the psychometric determination of retinal straylight using the compensation comparison method. METHODS Thirteen emmetropic subjects were randomly fitted with two different tinted Nike Maxsight (Bausch & Lomb, Rochester, NY, USA) CL in one eye, while the contralateral eye was fitted with a clear lens made of the same material (Optima 38, Bausch & Lomb). Three valid straylight measurements were taken on each eye before and a few minutes after lens insertion, when lens stabilization had occurred. RESULTS The subjects' mean straylight values were 0.90 +/- 0.09 at baseline and 0.95 +/- 0.10 with the clear Optima 38 CL. Straylight values were 0.97 +/- 0.10 and 1.0 +/- 0.10 log units with the amber and grey-green tinted CL, respectively. Differences in straylight between baseline (without CL) and with the clear CL in place were neither statistically significant (p = 0.066) nor was there a significant difference between baseline and the amber CL (p = 0.052). However, the grey-green CL showed a statistically significant difference from baseline (p = 0.006). Differences in straylight with the clear CL compared with the grey-green CL were also statistically different from zero (p = 0.002) showing an increased straylight value for the tinted CL. These differences were variable, but consistent for each subject, thus those showing higher or lower changes with one tinted lens tended to show the same trend with the second lens (r(2) = 0.736). CONCLUSIONS Despite increases having been found in straylight values with tinted contact lenses, those changes are not likely to induce clinically significant changes in visual function under photopic conditions, even for the grey-green CL, which seems to increase straylight values more significantly than the amber CL. This difference between the tinted CL could suggest a wavelength dependence of straylight values, although this should be investigated further by controlling for pupil size and subjects' pigmentation, as well as by using neutral density filters.
منابع مشابه
Enhancement of contrast sensitivity and losses of chromatic discrimination with tinted lenses.
PURPOSE Tinted lenses for everyday use should not impair visual acuity and contrast sensitivity or cause radical changes in color perception. The main aim of this study was to compare the performance in contrast detection and color discrimination tasks of a set of tinted lenses with that of gray filters of equal luminance under D65. METHODS The contrast sensitivity functions of 10 observers w...
متن کاملEfficacy of two silicone-hydrogel contact lenses for bandage use after photorefractive keratectomy.
PURPOSE To evaluate the efficacy of two silicone hydrogel (SiH) contact lenses, approved for continuous wear for one week, following photorefractive keratectomy (PRK). METHODS Forty seven myopic patients (94 eyes) undergone bilateral PRK were enrolled in this prospective, double-masked, comparative study. One eye of each patient was fitted with a Lotrafilcon B lens (Ciba Vision, Duluth, US; 3...
متن کاملScanning Electron Microscopy Findings With Energy-Dispersive X-ray Investigations of Cosmetically Tinted Contact Lenses
OBJECTIVE To investigate the surfaces and principal elements of the colorants of cosmetically tinted contact lenses (Cos-CLs). METHODS We analyzed the surfaces and principal elements of the colorants of five commercially available Cos-CLs using scanning electron microscopy with energy-dispersive x-ray analysis. RESULTS In two Cos-CLs, the anterior and posterior surfaces were smooth, and col...
متن کاملPsychophysics, reliability, and norm values for temporal contrast sensitivity implemented on the two alternative forced choice C-Quant device.
The current paper describes the design and population testing of a flicker sensitivity assessment technique corresponding to the psychophysical approach for straylight measurement. The purpose is twofold: to check the subjects' capability to perform the straylight test and as a test for retinal integrity for other purposes. The test was implemented in the Oculus C-Quant straylight meter, using ...
متن کاملPerformance of the compensation comparison method for retinal straylight measurement: effect of patient's age on repeatability.
AIM The assessment of repeatability and reproducibility of retinal straylight measurements with the C-Quant straylight meter (Oculus AG, Germany) and the effect of patient's age on the instrument performance are tested with a series of experiments. METHODS First, 20 eyes from 20 subjects (mean age 26.9 (SD 2.7) years, mean refractive error -1.34 (2.72) D) were examined with the C-Quant strayl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians
دوره 28 2 شماره
صفحات -
تاریخ انتشار 2008