The relationship between 7T fMRI BOLD and MEG derived γ activity

نویسندگان

  • C. Stevenson
  • M. Brookes
  • P. Morris
چکیده

Introduction: The move to high field imaging is thought to be very beneficial for fMRI, promising an improved signal to noise ratio and increased BOLD contrast alongside increased spatial specificity [1]. It has been shown that the field strength dependence of the fractional signal change varies depending on the relative contributions of capillary and non-capillary venous vessels, with an increase proportional to B0 for large vessels (venules and veins; d>10μm) and B0 2 for small vessels (capillaries; d<10μm) [2]. Therefore, in moving from 3T to 7T one would expect an increase in the amplitude of the measured BOLD response, with an increase in weighting towards small vessels at 7T. It has been suggested that this makes BOLD data acquired at higher field strengths closer to the true site of neural activation as it is less dominated by draining veins. This increase in spatial specificity should also result in a response amplitude more closely related to true neuronal activity. MEG provides a non-invasive, direct measure of neural activity and previous studies have shown a good correlation between fMRI BOLD data and time-locked, nonphase locked oscillatory effects in MEG, particularly in the γ (60-80Hz) range [3]. Here, the induced oscillatory response in the γ-band is measured by MEG and the haemodynamic response is measured by fMRI at both 3T and 7T. The degree of modulation in gamma band activity due to a visual stimulus of varying contrast is compared to the variations in BOLD response at the two field strengths in order to determine whether 7T BOLD data is more closely related to the underlying neuronal activity than BOLD data acquired at 3T. Methods: Four healthy subjects took part in the study. The visual paradigm comprised a sinusoidal drifting grating, presented in a circular window in the lower left hand quadrant of the visual field with a visual angle of 5. Five contrasts (0, 0.125, 0.25, 0.5 and 1) were presented pseudo-randomly, with the stimulus presented for 4secs. Trial length was 8secs in MEG and 16 secs in fMRI. Experiments consisted of 20 trials per contrast in MEG and 8 trials per contrast in fMRI. MEG data were acquired at a sample rate of 600Hz, on a 275-channel CTF system. Coregistration to anatomical MRI was performed using head digitisation (Polhemus Isotrack). Contiguous axial slices covering the visual cortex were acquired on both 3T and 7T Philips Achieva systems running GE-EPI (3T:TR=2000ms, TE=40ms, 3x3x3mm voxels, 192mm FOV, 18 slices, SENSE factor 2) (7T:TR=2000ms, TE=25ms, 2x2x2mm voxels, 156mm FOV, 15 slices, SENSE factor 1.5). Data Analysis: Areas of significant (p=0.05 corrected) BOLD contrast were identified using SPM5. 9mm cubic regions centred on the global maxima were used to obtain average time-courses of the haemodynamic response. BOLD derived contrast response curves were obtained by integration of the BOLD timecourse. Contrast to noise ratio was computed for significantly active voxels acquired during the 100% Michelson contrast condition. The 0% contrast trials formed the baseline and the variance of this signal was taken to be the noise variance. CNR was computed using ΔS/N, where ΔS is the difference in MR signal between active and baseline states and N is the noise variance of the voxel in question. Given the difference in voxel size at 3T and 7T, with a voxel volume of 8mm being employed at 7T in comparison to 27mm at 3T, it is difficult to directly compare CNR. However, it has been assumed here that if similar values of mean CNR are achieved at both field strengths, then any reduction in activated volume is due to underlying physical differences in the signal rather than signal to noise differences. For ease of comparison, values were converted to volume of activation with a given CNR by multiplying the number of voxels with each CNR by the voxel volume used at each field strength. MEG data were analysed using synthetic aperture magnetometry (SAM) [4]. Spatial localisation of γ activity was achieved by comparison of oscillatory power in an active contrast window, spanning the stimulus presentation time (0.1-4s), and a passive time window spanning the post-stimulus rest period (4.1-8s). Pseudo T-stat images [4] (1mm resolution) were created showing regions of activity within the γ band. Virtual sensor traces were located in peaks of activity in the SAM images and time courses of electrical oscillatory power were obtained by applying a Hilbert transform of the virtual sensor data and averaging across trials. Modulation of the γ response was assessed by integration of the Hilbert envelope. MEG derived contrast response curves were correlated with the respective BOLD contrast response curves obtained at both field strengths on a subject by subject basis. Results and Discussion: Figure 1 shows a compelling agreement in spatial localisation of the peaks in γ band activity and BOLD data for both 3T and 7T experiments. A single peak of γ activity, depicted by an increase in power during stimulation, was found in all four subjects in central visual areas, contra-lateral to stimulus presentation. This was spatially coincident with the global maxima in BOLD data. Significant BOLD activity was also seen at both 3T and 7T bilaterally and in more lateral visual areas responsible for motion encoding. As can be seen in Figure 1 the 7T data is the more focal of the two responses, with a volume of significant activity of 570±120mm in comparison to 980±480mm at 3T. This is also reflected in Figure 2 which shows a smaller total volume of significant activation at 7T but similar mean CNR values (4.97 at 3T and 4.78 at 7T) , suggesting that despite the smaller voxel volume used at 7T, the difference in volume of activation is not due to differences in signal to noise ratio. Figure 3 shows the correlation coefficient between the contrast response curve derived using the electrical oscillatory activity and the BOLD derived contrast response curves at 3 and 7T, with all four subjects showing an increase in correlation with the 7T BOLD data. The average correlation coefficient at 3T was 0.5±0.2 and 0.8±0.1 at 7T with the level of significance of the increased correlation at 7T being p=0.068. Conclusion: The co-localisation of BOLD peaks and peaks in γ activity strongly suggests that these processes are intimately linked. The increased spatial specificity of 7T BOLD data in comparison to 3T data is demonstrated. A similar mean CNR in the two data sets suggests that the reduction in the volume of significant activity at 7T is due to an increased weighting towards small vessels rather than differences in signal to noise ratio. The increase in correlation between the gamma band contrast response curve and the 7T contrast response curve suggests that the due to the increased spatial specificity of the 7T BOLD data and the reduction in venous weighting, the resulting haemodynamic response has an amplitude more closely related to the neuronal activity than BOLD data measured at 3T. References: [1]T.Q. Duong et. al . Magn. Reson. Med. 48(2002) 589-593, [2]S. Ogawa et al., Biophys. J. 64(1993)803-812[3]M.J. Brookes et al. NeuroImage 26(2005) 302-308, [4]S.E. Robinson et. al., Biomag 98, 11th Int Conf on Biomagnetism, 1998. Figure 3: Correlation coefficients of γ band contrast response curves and BOLD derived contrast response curves at 3T (blue) and 7T (red) on a subject by subject basis. Far right shows the average results shown with standard error. Figure 2: A histogram of volume of significant activity (p<0.05) vs contrast to noise ratio for 3T (blue) and 7T (red) data, averaged across subjects. Black vertical line shows mean CNR at 3T. 0 5 10 15 20 25 0 200 400 600 80

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Deconvolved fMRI correlates with source-localised MEG as a function of neural frequency oscillation

Introduction: The relationship between neuronal events and haemodynamic changes measured with blood-oxygenation-level-dependent (BOLD) functional MRI (fMRI) is still unknown, although many recent studies have provided a qualitative correspondence. The local neuromagnetic fields generated by the dendrites of cortical pyramidal cells can be measured non-invasively at the scalp with magnetoencepha...

متن کامل

Combined MEG and fMRI model

An integrated model for magnetoencephalography (MEG) and functional Magnetic Resonance Imaging (fMRI) is proposed. In the proposed model, MEG and fMRI outputs are related to the corresponding aspects of neural activities in a voxel. Post synaptic potentials (PSPs) and action potentials (APs) are two main signals generated by neural activities. In the model, both of MEG and fMRI are related to t...

متن کامل

BOLD responses in human auditory cortex are more closely related to transient MEG responses than to sustained ones.

Blood oxygen level dependent-functional magnetic resonance imaging (BOLD-fMRI) and magnetoencephalographic (MEG) signals are both coupled to postsynaptic potentials, although their relationship is incompletely understood. Here, the wide range of BOLD-fMRI and MEG responses produced by auditory cortex was exploited to better understand the BOLD-fMRI/MEG relationship. Measurements of BOLD and MEG...

متن کامل

The electrophysiological basis of negative BOLD in default mode network

Introduction: The default mode network (DMN) [1], which includes medial prefrontal cortex (MPFC), posterior cingulate cortex (PCC), precuneus and the left and right inferior parietal lobules (IPLs), has been widely investigated using fMRI. The network is characterised by high intrinsic correlation between BOLD signals measured at separate network nodes in the resting state, implying functional ...

متن کامل

BOLD Responses in Human Primary Visual Cortex are Insensitive to Substantial Changes in Neural Activity

The relationship between blood oxygenation level dependent-functional magnetic resonance imaging (BOLD-fMRI) and magnetoencephalography (MEG) metrics were explored using low-level visual stimuli known to elicit a rich variety of neural responses. Stimuli were either perceptually isoluminant red/green or luminance-modulated black/yellow square-wave gratings with spatial frequencies of 0.5, 3, an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008