Arterial pressure at zero flow (Pz = 0) that is higher than venous pressure (Pv) in dynamic pressure-flow relations has been explained by the presence of an arteriolar Starling resistor (SR) mechanism (i.e., vascular waterfall) or the discharge of vascular capacitance. To determine which was predominant, I studied in vivo hind limbs of 18 anesthetized dogs in which femoral arteries were cannulated with in-line electromagnetic flow probes to measure inflow (Qin), Pv was controlled, and collateral flow was eliminated with a tourniquet. Pz = 0 was obtained by turning flow to zero. Three tests were applied: 1) Pv was raised in steps with either constant Qin or constant arterial pressure (Pa) to determine the pressure at which upstream vascular characteristics were affected by a change in Pv, 2) the time to reach Pz = 0 was varied to determine compliance effects, and 3) an equation was developed to determine if experimentally derived parameters could explain Pz = 0 without invoking an SR. With constant Qin and a Pz = 0 of 56.9 +/- 11.7 mm Hg (time to Pz = 0, 3 seconds), Pv could be raised by 9.6 +/- 6.2 to 16.3 +/- 6.0 mm Hg before Pa increased, and with constant Pa, Pv could be raised by 6.8 +/- 7.3 to 14.0 +/- 8.0 mm Hg before Qin decreased. With increasing times to reach Pz = 0, Pz = 0 initially dropped precipitously, but then decreased by only a small amount over the next 5-10 seconds even though arterial pressure was much above Pv. This could be explained by an SR mechanism with a critical pressure of 42.3 +/- 11.4 mm Hg and an arterial compliance of 0.0104 +/- 0.0023 ml.mm Hg-1 (n = 6). There was no value for the compliance that described the results when the arterial outflow pressure was Pv. Thus, this study supports the hypothesis that an SR mechanism is present in the vascular system. It is most likely precapillary, and in the resting limb, it has a value of 40-50 mm Hg. However, Pz = 0 in dynamic pressure-flow studies of less than 4 seconds is also greatly influenced by capacitance effects and the initial Pa.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comments and Opinions Transition to Collateral Flow After Arterial Occlusion Predisposes to Cerebral Venous Steal

Background and Purpose—Stroke-related tissue pressure increase in the core and penumbra determines regional cerebral perfusion pressure (rCPP) defined as a difference between local inflow pressure and venous or tissue pressure, whichever is higher. We previously showed that venous pressure reduction below the pressure in the core causes blood flow diversion–cerebral venous steal. Now we investi...

متن کامل

Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall

Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been  introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the  substitution  of  the  blood  pressure  changes  in  the  central  arteries  such  as  carotid  with  the  blood  pressure  changes in the brachial results in error in the blood...

متن کامل

Transition to collateral flow after arterial occlusion predisposes to cerebral venous steal.

BACKGROUND AND PURPOSE Stroke-related tissue pressure increase in the core and penumbra determines regional cerebral perfusion pressure (rCPP) defined as a difference between local inflow pressure and venous or tissue pressure, whichever is higher. We previously showed that venous pressure reduction below the pressure in the core causes blood flow diversion-cerebral venous steal. Now we investi...

متن کامل

Counterpoint: the classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is not correct.

Interactions in Health and Disease, edited by Scharf SM, Pinsky, and Magder S. New York: Marcel Dekker, 2001, p. 93–112. 16. Magder S. Starling resistor versus compliance. Which explains the zeroflow pressure of a dynamic arterial pressure-flow relation? Circ Res 67: 209–220, 1990. 17. Magder S. More respect for the CVP. Int Care Med 24: 651–653, 1998. 18. Magder S. Theoretical analysis of the ...

متن کامل

LETTERS TO THE EDITOR Comments on Flow through Collapsible Tubes at Low Reynolds Numbers

In a recent paper by Lyon et al. (Flow through Collapsible Tubes at Low Reynolds Numbers. Circ Res 47: 68-73, 1980), the authors contend that waterfall models adequately predict flow through a Starling resistor only for Reynolds numbers <1. Their basic conclusion was that caution should be used when applying waterfall models to the mammalian circulatory system since Reynolds numbers are usually...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 67 1  شماره 

صفحات  -

تاریخ انتشار 1990