Photomultiplier Tubes

ثبت نشده
چکیده

including basic and performance. For example, section 4.1 shows spectral response characteristics of typical photocathodes and also gives the definition of photocathode sensitivity and its measurement procedure. Section 4.2 explains dynode types, structures and typical characteristics. Section 4.3 describes various performance characteristics such as time response, operating stability, sensitivity, uniformity, and signal-to-noise ratio as well as their definitions, measurement procedures and specific product examples. It also provides precautions and suggestions for use. CHAPTER 4 CHARACTERISTICS OF PHOTOMULTIPLIER TUBES

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative assessment of the accuracy of maximum likelihood and correlated signal enhancement algorithm positioning methods in gamma camera with large square photomultiplier tubes

Introduction: The gamma cameras, based on scintillation crystal followed by an array of photomultiplier tubes (PMTs), play a crucial role in nuclear medicine. The use of square PMTs provides the minimum dead zones in the camera. The camera with square PMTs also reduces the number of PMTs relative to the detection area. Introduction of a positioning algorithm to improve the spat...

متن کامل

Parameterisation of the angular response of the R1408 Hamamatsu eight-inch photomultiplier tube to be used in the Sudbury Neutrino Observatory

This paper describes measurements made on Hamamatsu R1408 8-m. photomultiplier tubes in order to parameterise the cesium bialkali photocathode in terms of a complex refractive index fi and a thickness T. The extracted parameters have been used to predict the angular response of the photomultiplier tubes, and this prediction has been experimentally verified. Measurements were taken on a number o...

متن کامل

Improvement of 20 in. diameter photomultiplier tubes

The quality of the 20 in . photomultiplier tubes (Hamamatsu R1449) has been greatly improved over the required specifications for using them m the 50000 ton imaging water Cherenkov detector, Super-Kamiokande . In particular, the resolution of the timing response for single-photoelectron light has been reduced to 3 ns (1Q width), and a clear single-photoelectron peak can be seen in the pulse hei...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007