Rapid Separation and Quantification of Iron in Uranium Nuclear Matrix by Capillary Zone Electrophoresis (CZE)

نویسندگان

  • Vivekchandra Mishra
  • Mrinal Kanti Das
  • Subbiah Jeyakumar
  • Ramesh Mahadeo Sawant
چکیده

A method was developed for rapid separation and determination of iron by employing capillary zone electrophoresis (CZE) technique with direct UV detection. Iron could be separated from matrix uranium by direct injection of dissolved sample solution into capillary using a mixture of 10 mM HCl and 65 mM KCl (pH = 2) as background electrolyte (BGE) at an applied voltage of 15 kV. The developed method has a very high tolerance for the matrix element U (100 mg/mL) and as such may not need prior separation of iron from the matrix. Iron could be separated with better than 95% recovery. The method showed a linear calibration over a concentration range 1-50 ppm of Fe(III). The migration times for the iron peak were reproducible within 1% for both pure Fe(III) and in presence of matrix uranium (80 mg/mL). The precision (RSD, n = 22) of peak area obtained for 1 ppm of iron was 3.5%. The limit of detection (LOD) (3) was 0.1 ppm and the absolute LOD was 9 × 10 g considering the sample injection volume of 1.5 nL. The developed method has been validated by separating and determining iron in two certified reference materials of U3O8. The method was applied for the determination of iron in different uranium based nuclear materials. The CZE method is versatile for routine analysis as it is simple, rapid and has simple sample preparation procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid Biomolecule Analysis Using Two-dimensional Electrophoresis-electrospray Ionization Microchip

We demonstrate a two-dimensional (2D) separation microchip allowing capillary isoelectric focusing-capillary zone electrophoresis (cIEF-CZE) to be coupled to electrospray ionization mass spectrometry (ESI/MS). In the first dimension, separation is according to pI values (cIEF), while CZE occurs in the second dimension during mobilization towards the monolithically integrated ESI emitter. The se...

متن کامل

Analysis of N-acylhomoserine lactones after alkaline hydrolysis and anion-exchange solid-phase extraction by capillary zone electrophoresis-mass spectrometry.

A quantitative, specific, and sensitive method for the determination of N-acylhomoserine lactones (HSLs - a group of bacterial semiochemicals) in the form of their hydrolysis products (N-acylhomoserines, HSs) is presented. Real samples were analyzed by capillary zone electrophoresis-mass spectrometry (CZE-MS) after alkaline lactonolysis and extraction by mixed-mode anion-exchange solid-phase ex...

متن کامل

A stability indicating capillary electrophoresis method for analysis of buserelin

A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seco...

متن کامل

Improved CZE capabilities with new dynamic coatings.

Electroosmotic flow (EOF) is one of the fundamental processes affecting both resolution and separation times in capillary zone electrophoresis (CZE). EOF is a function of pH and buffer composition (zeta potential) in bare-silica capillaries at any pH above 3 and runs in the cathodal direction, decreasing the effective separation length for cationic species. On the other hand, the absence of EOF...

متن کامل

A stability indicating capillary electrophoresis method for analysis of buserelin

A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seco...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011