Detection of awareness in surgical patients with EEG-based indices--bispectral index and patient state index.
نویسندگان
چکیده
BACKGROUND Patient state index (PSI) and bispectral index (BIS) are values derived from the EEG, which can measure the hypnotic component of anaesthesia. We measured the ability of PSI and BIS to distinguish consciousness from unconsciousness during induction and emergence from anaesthesia and a period of awareness in surgical patients. METHODS Forty unpremedicated patients were randomized to receive: (1) sevoflurane/remifentanil (< or =0.1 microg kg(-1) min(-1)), (2) sevoflurane/remifentanil (> or = 0.2 microg kg(-1) min(-1)), (3) propofol/remifentanil (< or =0.1 microg kg(-1) min(-1)), (4) propofol/remifentanil (> or = 0.2 microg kg(-1) min(-1)). Every 30 s after the start of the remifentanil, patients were asked to squeeze the investigator's hand. Sevoflurane or propofol were given until loss of consciousness (LOC1). Tunstall's isolated forearm technique was used during neuromuscular block with succinylcholine. After tracheal intubation, propofol or sevoflurane were stopped until return of consciousness (ROC1). Propofol or sevoflurane were re-started to induce LOC2. After surgery, drugs were discontinued and recovery (ROC2) was observed. PSI and BIS at LOC (LOC1 and LOC2) were compared with those at ROC (ROC1 and ROC2) (t-test). Prediction probability (P(k)) was calculated from values at the last command before and at LOC and ROC. Values are mean (SD). RESULTS At non-responsiveness, BIS (66 (17)) and PSI (55 (23)) were significantly less than at responsiveness (BIS, 79 (14); PSI, 77 (18); P<0.05). The wide variation with both BIS and PSI measurements of the 80 'awareness' values led to an erroneous classification as unconscious in some cases (BIS, six patients; PSI, nine patients). P(k) was 0.68 (0.03) (BIS) and 0.69 (0.03) (PSI). CONCLUSIONS Despite significant differences between mean values at responsiveness and non-responsiveness for BIS and PSI, neither measure may be sufficient to detect awareness in an individual patient, reflected by a P(k) less than below 70%.
منابع مشابه
EEG-based indices of anaesthesia: correlation between bispectral index and patient state index?
BACKGROUND AND OBJECTIVE Both the bispectral and the patient state indices are derived from the electroencephalogram and have been proposed as a measure of the same clinical target, the hypnotic component of anaesthesia. The present study evaluated whether there is concordance between the bispectral and the patient state indices with regard to end-points measured simultaneously in patients unde...
متن کاملComparison of Bispectral Index and Entropy values with electroencephalogram during surgical anaesthesia with sevoflurane.
BACKGROUND Concomitantly recorded Bispectral Index® (BIS) and Entropy™ values sometimes show discordant trends during general anaesthesia. Previously, no attempt had been made to discover which EEG characteristics cause discrepancies between BIS and Entropy. We compared BIS and Entropy values, and analysed the changes in the raw EEG signal during surgical anaesthesia with sevoflurane. METHODS...
متن کاملتاثیر سن بالا بر روی شاخص دو طیفی (Bispectral Index) قبل و بعد از تزریق آرامبخش: یک مطالعه آیندهنگر
Background: The Bispectral Index (BIS) is an EEG-derived value that measures the sedative and hypnotic component of the anesthetic state. The effects of age on the bispectral index have not been well documented. The objective of the present study was to determine the influence of age on hypnotic requirement and bispectral index in awake and in patients with sedation induced by midazolam.Methods...
متن کاملEvaluation of the Adequacy of General Anesthesia in Cesarean Section by Bispectral Index
Background: Awareness and recall, though not common, are the major hazards of general anesthesia, especially in Cesarean section (C/S) because of the absence of benzodiazepine and opioids for a significant time during anesthesia. In this study, the Bispectral Index (BIS), end-tidal isoflurane, and hemodynamic parameters were examined to evaluate the depth of the routine general anesthetic techn...
متن کاملChanges in the electroencephalogram during anaesthesia and their physiological basis.
The use of EEG monitors to assess the level of hypnosis during anaesthesia has become widespread. Anaesthetists, however, do not usually observe the raw EEG data: they generally pay attention only to the Bispectral Index (BIS™) and other indices calculated by EEG monitors. This abstracted information only partially characterizes EEG features. To properly appreciate the availability and reliabil...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 91 3 شماره
صفحات -
تاریخ انتشار 2003