A Robust Infrastructure for Data Collection and Transfer for a Distributed SRAM-based Neutron Detection Platform
نویسندگان
چکیده
This paper introduces the architecture of a robust communication framework, which allows high quality data exchange for a distributed neutron detection system that works in a radiating environment. This distributed system needs a reliable data transfer infrastructure, since both the infrastructure and the sensing electronics are exposed to radiations but the former must keep error resilient. For this purpose, we introduced some redundancy in data transfer and provided diagnostic protocols to identify the faulty elements of the system and, when required, to isolate them.
منابع مشابه
A harmony search-based approach for real-time volt & var control in distribution network by considering distributed generations units
In recent decade, development of telecommunications infrastructure has led to rapid exchange of data between the distribution network components and the control center in many developed countries. These changes, considering the numerous benefits of the Distributed Generators (DGs), have made more motivations for distribution companies to utilize these kinds of generators more than ever before. ...
متن کاملThe effect of source shield on landmine detection
Background: Several landmine detection methods, based on nuclear techniques, have been suggested during the recent years. Neutron energy moderation, neutron-induced gamma emission, neutron and gamma attenuation, and fast neutron backscattering are nuclear-based methods used for landmine detection. The aim of this study is to use backscattered neutron for landmine detection. Materials ...
متن کاملThe safety of a landmine detection system using graphite and polyethylene moderator
Background: Several landmine detection methods, based on nuclear techniques, have been suggested up to now. Neutron-induced gamma emission, neutron and gamma attenuation, and fast neutron backscattering are the nuclear methods used for landmine detection. In this paper an optimized (safe and effective) moderating structure using an 241Am-Be neutron source for detecting landmines has been invest...
متن کاملSynergetic signal amplification of multi-walled carbon nanotubes-Cetyltrimethylammonium Bromide and Poly-L-Arginine as a highly sensitive detection platform for Rutin
In this research, a glassy carbon electrode was coated with a thin layer of multi-walled carbon nanotubes in the presence of the surfactant and subsequently was electro-polymerized with Poly-L-arginine (P-L-Arg). The prepared electrode was used as an effective sensor for the quantitative detection of Rutin (Ru). The fabricated electrode exhibited good electrochemical performance with low electr...
متن کاملSynergetic signal amplification of multi-walled carbon nanotubes-Cetyltrimethylammonium Bromide and Poly-L-Arginine as a highly sensitive detection platform for Rutin
In this research, a glassy carbon electrode was coated with a thin layer of multi-walled carbon nanotubes in the presence of the surfactant and subsequently was electro-polymerized with Poly-L-arginine (P-L-Arg). The prepared electrode was used as an effective sensor for the quantitative detection of Rutin (Ru). The fabricated electrode exhibited good electrochemical performance with low electr...
متن کامل