Endoscopes and devices to improve colon polyp detection.

نویسندگان

  • Vani Konda
  • Shailendra S Chauhan
  • Barham K Abu Dayyeh
  • Joo Ha Hwang
  • Sri Komanduri
  • Michael A Manfredi
  • John T Maple
  • Faris M Murad
  • Uzma D Siddiqui
  • Subhas Banerjee
چکیده

The American Society for Gastrointestinal Endoscopy (ASGE) Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, with a MEDLINE literature search to identify pertinent clinical studies on the topic, and a MAUDE (Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported adverse events of a given technology. Both are supplemented by accessing the “related articles” feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but, in many cases, data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the committee as a whole, and approved by the governing board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review the MEDLINE database was searched through March 2014 for articles related to endoscopy in patients with colon polyps by using the keywords “colon polyp,” “colon adenoma,” and “colon neoplasm” paired with “colonoscopy,” “third eye retroscope,” “cap-fitted,” “cap-assisted,” “transparent cap,” “retroflexion,” “cuff,” “endoscope,” “colonoscope,” “detection,” “wide-angle,” and “full spectrum endoscope.” Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New endoscopes and add-on devices to improve colonoscopy performance

Colonoscopy is the gold standard for colorectal cancer prevention; however, it is still an imperfect modality. Precancerous lesions can be lost during screening examinations, thus increasing the risk of interval cancer. A variety of factors either patient-, or endoscopist dependent or even the procedure itself may contribute to loss of lesions. Sophisticated modalities including advanced techno...

متن کامل

Devices to improve colon polyp detection.

m h m a s b The ASGE Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidencebased methodology is used, performing a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database searc...

متن کامل

Radioiodine avid adenomatous colon polyp in a post-treatment whole body radioiodine scan

A 47 year old female with papillary thyroid carcinoma was referred to our department for post-treatment whole body iodine scanning. The acquired images revealed a focal zone of intense radiotracer uptake in the right lower quadrant of the abdomen. SPECT/CT fused slices showed a focal zone of the radioiodine (131I) uptake in the right colon wall. Colonoscopy revealed a pedunculated po...

متن کامل

Colorectal Adenoma – Resection Techniques and Surveillance

Egger: The most important condition for the detection of polyps in the colon is a good bowel preparation. A high resolution endoscope is required – at best the latest scope generation. Another important point is the withdrawal time, which should be long enough. One or two experienced nurses as two or four additional eyes will be helpful. In the future, endoscopes with a wider angle or side view...

متن کامل

Screening colonoscopy: should we focus more on technique and less on technology?

Several large studies have confirmed that high quality colonoscopic surveillance can improve outcomes with substantial reduction in colorectal cancer rates. In order to improve outcomes from screening colonoscopy and help detect adenomas, the emphasis has been mainly on improvements in technology like high-resolution scopes, computerized as well as dye-based chromoendoscopy and wide-angle endos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Gastrointestinal endoscopy

دوره 81 5  شماره 

صفحات  -

تاریخ انتشار 2015