Scoliosis and interspinous decompression with the X-STOP: prospective minimum 1-year outcomes in lumbar spinal stenosis.

نویسندگان

  • Kevin W Rolfe
  • James F Zucherman
  • Dimitriy G Kondrashov
  • Ken Y Hsu
  • Emily Nosova
چکیده

BACKGROUND CONTEXT The X-STOP interspinous decompression device, as a treatment for neurogenic intermittent claudication (NIC) because of lumbar spinal stenosis (LSS), has been shown to be superior to nonoperative control treatment. Current Food and Drug Administration labeling limits X-STOP use to NIC patients with a maximum of 25° concomitant lumbar scoliosis. This value was arrived at arbitrarily by the device developers and is untested. PURPOSE To determine X-STOP utility for NIC in patients with concomitant lumbar scoliosis. STUDY DESIGN A prospective, single institution, clinical outcome study comparing patients with scoliosis with patients without scoliosis who underwent X-STOP interspinous decompression for NIC because of LSS. PATIENT SAMPLE A cohort of 179 consecutive patients, 63 with scoliosis (Cobb angle 11° or more) and 116 without scoliosis, with symptoms attributable to NIC treated between January 2006 and May 2007, were included in the study. OUTCOME MEASURES All patients completed self-reported preoperative and minimum 1-year postoperative outcome forms. Functional measures included Oswestry Disability Index (ODI), visual analog scale (VAS) pain score, and maximum walking and standing times in minutes. Three questions measured patient satisfaction: How satisfied were you with the procedure (very satisfied, somewhat satisfied, somewhat dissatisfied, or very dissatisfied); Would you have the procedure again? (yes or no); Would you recommend the procedure to a friend? (yes or no). METHODS Before analysis, the 179 consecutive X-STOP patients were divided into three groups: Group 1 (controls without scoliosis, n=116); Group 2 (low scoliosis: 11-25°, n=41), and Group 3 (high scoliosis: 26° or more, n=22). The three groups were not statistically different for any preoperative functional scores. Groups were analyzed for pre- to postoperative functional change and level of satisfaction. Segmental scoliosis at the treated level was also analyzed. RESULTS Fifty-six percent of Group 1 and Group 2 patients, but only 18% of Group 3 patients, achieved the success criterion of an ODI improvement of 15 or more points (Group 3 the outlier, p=.004). The satisfaction rate was Group 1, 76%; Group 2, 78%; Group 3, 59% (Group 3 the outlier, p=.0001). On average, all three groups improved for each outcome: Group 1 (ODI 17.3, VAS 2.0, standing time 39 minutes, and walking time 43 minutes), Group 2 (ODI 20.0, VAS 1.9, standing time 65 minutes, and walking time 64 minutes), Group 3 (ODI 7.2, VAS 0.9, standing time 18 minutes, and walking time 16 minutes). There was no statistical relationship between any outcome and segmental scoliosis. CONCLUSIONS The outcome success rate for the X-STOP procedure to treat NIC is lower in patients with overall lumbar scoliosis more than 25° but is unaltered by segmental scoliosis at the affected level. Although patients and surgeons must be aware that the presence of more than 25° of scoliosis portends less favorable results with X-STOP implantation for NIC because of LSS, success in these patients is not precluded, and selection of treatment must be put into the context of individual patient risk and other treatment options.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The cost effectiveness of dynamic and static interspinous spacer for lumbar spinal stenosis compared with laminectomy

Background: The present study aims to evaluate the cost-effectiveness of Dynamic Interspinous Spacer (Coflex®) and Static Spacer (X-STOP ®) compared to Laminectomy (LAMI) in patients with lumbar spinal stenosis.   Methods: A decision-analysis model was developed to estimate the cost-effectiveness. The effectiveness parameters were obtained from a systematic literature review in ...

متن کامل

Interspinous process decompression with the X-STOP device for lumbar spinal stenosis: a 4-year follow-up study.

X-STOP is the first interspinous process decompression device that was shown to be superior to nonoperative therapy in patients with neurogenic intermittent claudication secondary to spinal stenosis in the multicenter randomized study at 1 and 2 years. We present 4-year follow-up data on the X-STOP patients. Patient records were screened to identify potentially eligible subjects who underwent X...

متن کامل

Surgical treatment of lumbar spinal stenosis with microdecompression and interspinous distraction device insertion. A case series

BACKGROUND Interspinous distraction devices (IPDD) are indicated as stand-alone devices for the treatment of spinal stenosis. The purpose of this study is to evaluate the results of patients undergoing surgery for spinal stenosis with a combination of unilateral microdecompression and interspinous distraction device insertion. METHODS This is a prospective clinical and radiological study of m...

متن کامل

Treatment of 44 Cases With Lumbar Spine Stenosis and Degenerative Instability: Outcomes of Surgical Intervention

Background and Aim: Degenerative lumbar spine disease can lead to lumbar spine instability. The patients can present with Low Back Pain (LBP), radicular pain, and motor and sensory dysfunction. Age >50, female sex and pregnancies are among prevalent risk factors. The degeneration process usually starts from the intervertebral discs progressing to involve facet joints, ligaments, and vertebral b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The spine journal : official journal of the North American Spine Society

دوره 10 11  شماره 

صفحات  -

تاریخ انتشار 2010