Investigation on the optimal properties of semi active control devices with continuous control for equipment isolation
نویسندگان
چکیده
The paper treats the semi active isolation of a single equipment, acceleration sensitive, by means of a variable elastic control device. A numerical study on a single degree of freedom (SDOF) structural model equipped with a continuously variable elastic device subjected to harmonic input is presented. The utilized control algorithm is derived by the Lyapunov method and specialized in order to obtain instantaneous optimality. In order to minimize the dynamic response of interest, i.e. the equipment absolute acceleration, some parameters that define the algorithm and the device are conveniently selected. The purpose of the paper is to investigate the optimal isolation properties of semi active variable stiffness devices with continuous control across the whole frequency spectrum. The performances of the isolated equipment are evaluated in terms of absolute acceleration transmissibility. Semi active continuous control is compared with semi active ON-OFF mode and conventional linear passive control. Results show that it is possible to choose conveniently the parameters regulating semi active continuous control in order to limit the absolute acceleration transmissibility at all the frequencies. In literature from problems concerning vibration isolation, transmissibility is alternatively defined in terms of absolute acceleration or displacement. Here, absolute displacement transmissibility is also estimated. It is observed that in case of semi active control, there are differences between the two transmissibility representations, and they do not lead to analogous results for evaluating the performance of the control system.
منابع مشابه
Semi-active Control of Building Structures using Variable Stiffness Device and Fuzzy Logic
Semi-active control devices, also called “Intelligent” control devices, constitute the positive aspects of both the passive and active control devices. A semi-active control strategy is similar to the active control strategy, but this control device has been shown to be more energy-efficient than active devices. A particular type of semi-active control device, the Variable Stiffness Device (VSD...
متن کاملINVESTIGATION OF THE OPTIMAL SEMI-ACTIVE CONTROL STRATEGIES OF ADJACENT BUILDINGS CONNECTED WITH MAGNETORHEOLOGICAL DAMPERS
This study investigates the efficacy of optimal semi-active dampers for achieving the best results in seismic response mitigation of adjacent buildings connected to each other by magnetorheological (MR) dampers under earthquakes. One of the challenges in the application of this study is to develop an effective optimal control strategy that can fully utilize the capabilities of the MR dampers. H...
متن کاملMULTI-OBJECTIVE SEMI-ACTIVE BASE ISOLATION SYSTEM
Semi-active base isolation system has been proposed mainly to mitigate the base drift of isolated structures while in most cases, its application causes the maximum acceleration of superstructure to be increased. In this paper, designing optimal semi-active base isolation system composed of linear base isolation system with low damping and magneto-rheological (MR) damper has been studied for co...
متن کاملAN OPTIMAL CUCKOO SEARCH-FUZZY LOGIC CONTROLLER FOR OPTIMAL STRUCTURAL CONTROL
An optimal semi-active Cuckoo- Fuzzy algorithm is developed to drive the hydraulic semi-active damper for effective control of the dynamic deformation of building structures under earthquake loadings, in this paper. Hydraulic semi-active dampers (MR dampers) are semi active control devices that are managed by sending external voltage supply. A new adaptive fuzzy logic controller (FLC) is introd...
متن کاملAn optimal semi-active thermal exchange-Fuzzy logic Controller for Structural Dynamic Control and Rehabilation
The effect of intelligent semi-active thermal exchange-fuzzy controller in structural rehabilitation by attenuating seismic responses of structural systems is investigated. In the suggested control system, MR dampers and sensors are employed as a semi-active controller. Resultant control forces of MR damper are administrated by providing external voltage supply, during the earthquakes and high ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Scalable Computing: Practice and Experience
دوره 15 شماره
صفحات -
تاریخ انتشار 2014