The reliability of a portable clinical force plate used for the assessment of static postural control: repeated measures reliability study
نویسندگان
چکیده
UNLABELLED BACKGROUND Force plates are frequently used for postural control assessments but they are expensive and not widely available in most clinical settings. Increasingly, clinicians are using this technology to assess patients, however, the psychometric properties of these less sophisticated force plates is frequently unknown. The purposes of the study were to examine the test-retest reliability of a force plate commonly used by clinicians and to explore the effect of using the mean value from multiple repetitions on reliability. METHODS Thirty healthy volunteer adults were recruited. Postural control measures were obtained using the Midot Posture Scale Analyzer (MPSA). Data were collected in 2 sessions. Five successive repetitions each of 60 seconds duration were obtained from each participant in each session. RESULTS The reliability coefficients obtained using single measures were low (ICC3,1 = 0.06 to 0.53). The average of two measures allowed for reliable measurements of COP mean velocity and average location of COP. The average of three and five measures was required to obtain acceptable reliability (ICC ≥ 0.70) of relative weight bearing on legs and sway area, respectively. Higher measurement precision values were seen by averaging four or five repetitions for all variables. CONCLUSION Single measures did not provide reliable estimates of postural sway, and the averaging of multiple repetitions was necessary to achieve acceptable levels of measurement error. The number of repetitions required to achieve reliable data ranged from 2 to 5. Clinicians should be wary of using single measures derived from similar equipment when making decisions about patients.
منابع مشابه
The validity of a portable clinical force plate in assessment of static postural control: concurrent validity study
UNLABELLED BACKGROUND The broad use of force plates in clinical settings for postural control assessment suggests the need for instruments that are easy to use, affordable and readily available. In addition, these instruments of measurement should be reliable and valid as adequate reliability and validity are prerequisites to making correct inferences. The aim of this study was to examine th...
متن کاملResponsiveness of Static and Dynamic Postural Balance Measures in Patients with Anterior Cruciate Ligament Reconstruction Following Physiotherapy Intervention
Background:The main goal of physiotherapy for patients with anterior cruciate ligament reconstruction (ACL-R) is to improve postural control and retain knee function. Therefore, clinicians need to use evaluative tools that assess postural changes during physiotherapy. To maximize the clinical utility of the results of these tools, the extracted measures should have appropriate psychometric prop...
متن کاملTest-Retest Reliability of Dynamic Postural Stability Measures in Healthy and Chronic Non-specific Low Back Pain Groups
Objective: The primary aim of the present study was to study the reliability of postural stability measures during whole body dynamic conditions, so they can be used in postural stability evaluations, investigations of injury mechanisms and assessments of treatment efficacy. Materials & Methods: Twelve healthy volunteers and 12 low back pain patients performed repeated trunk bending motions ...
متن کاملReliability and validity of an accelerometry based measure of static and dynamic postural stability in healthy and active individuals.
Postural stability is an important measure in both research and clinical practice. A portable, easy to use device that can provide higher resolution than current clinical tests may allow for better identification of patients or athletes with postural stability deficits. The purpose of this study was to evaluate the ability of a tri-axial accelerometer to quantify postural stability in a healthy...
متن کاملTest-retest reliability and minimal detectable change for center of pressure measures of postural stability in elderly subjects
Abstract Background: Postural instability has been identified as a potential precursor of falls in elderly subjects. Postural stability in quiet stance is commonly assessed with center of pressure (COP) measures. The purpose of this study was to determine testretest reliability and minimal detectable change (MDC) for the center of pressure (COP) measures in the elderly subjects. Met...
متن کامل