BACKGROUND Resuscitation guidelines recommend that chest compressions should continue throughout attempts to place airway devices. Few data support the use of the tracheal tube over supraglottic airway devices (SADs) during cardiopulmonary arrest. This study was designed to evaluate the speed with which different airway devices could be placed with and without interrupting chest compressions. METHODS Forty volunteer doctors regularly involved in cardiopulmonary resuscitation (CPR) were timed inserting four different airway devices [tracheal tube (TT), LMA Classic (cLMA), LMA ProSeal (PLMA), and igel] into a manikin, with and without stopping chest compressions. RESULTS Chest compressions delayed the placement of the TT only (3.3 s, P<0.0001). Comparison of the speed of insertion of the different airway devices during CPR enabled ranking of the devices: igel (fastest), PLMA (second), and TT and cLMA (joint slowest). The igel was inserted approximately 50% faster than the other devices. Doctors who had previously inserted more than 50 tracheal tubes were significantly faster at intubating the trachea, but no faster at inserting SADs. CONCLUSIONS Our results show that continuing chest compressions has a minor effect on time for tracheal intubation and until clear human data are available the recommendation to intubate without interrupting CPR is therefore justified. The PLMA and igel (SADs with a gastric drain tube) were both faster to insert than the cLMA and offer additional benefits. They should be considered for use in CPR.
منابع مشابه
Can the ETView VivaSight SL Rival Conventional Intubation Using the Macintosh Laryngoscope During Adult Resuscitation by Novice Physicians?
UNLABELLED The aim of this study was to assess the performance of the ETView VivaSight SL (ETView) single-lumen airway tube with an integrated high-resolution imaging camera in a manikin-simulated cardiopulmonary resuscitation scenario with and without chest compression. This was a randomized crossover manikin trial. Following a brief training session, 107 volunteer novice physicians who were i...
متن کاملComparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries
Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...
متن کاملAccurate measurement of chest compression depth using impulse-radio ultra-wideband sensor on a mattress
OBJECTIVE We developed a new chest compression depth (CCD) measuring technology using radar and impulse-radio ultra-wideband (IR-UWB) sensor. This study was performed to determine its accuracy on a soft surface. METHODS Four trials, trial 1: chest compressions on the floor using an accelerometer device; trial 2: chest compressions on the floor using an IR-UWB sensor; trial 3: chest compressio...
متن کاملDoes a 4 diagram manual enable laypersons to operate the laryngeal mask supreme®? A pilot study in the manikin
BACKGROUND Bystander resuscitation plays an important role in lifesaving cardiopulmonary resuscitation (CPR). A significant reduction in the "no-flow-time", quantitatively better chest compressions and an improved quality of ventilation can be demonstrated during CPR using supraglottic airway devices (SADs). Previous studies have demonstrated the ability of inexperienced persons to operate SADs...
متن کاملComparison of Pentax-AWS Airwayscope and Glidescope for Infant Tracheal Intubation by Anesthesiologists during Cardiopulmonary Arrest Simulation: A Randomized Crossover Trial
BACKGROUND Recent guidelines for infant cardiopulmonary resuscitation emphasize that all rescuers should minimize interruption of chest compressions, even for endotracheal intubation. We compared the utility of the Pentax-AWS Airwayscope (AWS) with the Glidescope (GS) during chest compressions on an infant manikin. METHODS Twenty-four anesthesiologists with more than two years of experience p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 100 3 شماره
صفحات -
تاریخ انتشار 2008