Multiecho IDEAL gradient-echo water-fat separation for rapid assessment of cartilage volume at 1.5 T: initial experience.
نویسندگان
چکیده
Institutional review board approval and informed consent were obtained for this HIPAA-compliant study. The purpose was to prospectively compare multiecho iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) gradient-echo (GRE) magnetic resonance (MR) imaging with three-dimensional fat-suppressed (FS) spoiled GRE (SPGR) MR imaging to evaluate the articular cartilage of the knee. Six healthy volunteer and 10 cadaver knees were imaged at 1.5 T. Signal-to-noise ratio (SNR), SNR efficiency, and cartilage volume were measured. SNR and SNR efficiency were significantly higher with multiecho IDEAL GRE than with FS SPGR imaging (P < .031). Both methods produced equivalent cartilage volumes (overall concordance correlation coefficient, 0.998) with high precision and accuracy. The use of a cartilage phantom confirmed high accuracy in volume measurements and high reproducibility for both methods. Multiecho IDEAL GRE provides high signal intensity in cartilage and synovial fluid and is a promising technique for imaging articular cartilage of the knee.
منابع مشابه
Comparison of IDEAL, MultiPeak IDEAL and Fat-Saturated FSE for Imaging of Osteoarthritis (OA) Knee Patients: Initial Clinical Experience
INTRODUCTION Iterative Decomposition of Water and Fat with Echo Asymmetry and Least-Squares Estimation (IDEAL) is a promising MRI technique for robust fat and water separation (1). It was found with higher fluid/cartilage contrast-to-noise ratio efficiency and fat-suppression quality than FSE imaging in ankle. The goal of this study is to assess image quality, fat suppression and fat-water sepa...
متن کاملRapid MR imaging of articular cartilage with steady-state free precession and multipoint fat-water separation.
OBJECTIVE To obtain high-quality high-resolution images of articular cartilage with reduced imaging time, we combined a novel technique of generalized multipoint fat-water separation with three-dimensional (3D) steady-state free precession (SSFP) imaging. SUBJECTS AND METHODS The cartilage of 10 knees in five healthy volunteers was imaged with 3D SSFP imaging and a multipoint fat-water separa...
متن کاملPreliminary results of IDEAL fat/water separation at 9.4T
Introduction An iterative Dixon algorithm (IDEAL) [1] was established for efficient fat/water-separation during the last years. Here the method was executed invivo on a dead rat on 9.4T in order to verify the high-field performance of IDEAL. Data were acquired with a vendor supplied 3D multigradientecho sequence. Method Experiments were performed on a 9.4T Bruker Biospec 94/20 small animal scan...
متن کاملIterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) fast spin-echo imaging of the ankle: initial clinical experience.
OBJECTIVE Reliable, uniform fat suppression is important. Multiple approaches currently exist, many of which suffer from either suboptimal signal-to-noise ratio (SNR), or the inability to obtain consistent fat suppression around the ankle joint. Our purpose was to test iterative decomposition of water and fat with echo asymmetry and the least-squares estimation (IDEAL) method in combination wit...
متن کاملIDEAL at 7T in Mice Using Asymmetric Spin Echo and Gradient Echo Acquisitions
An asymmetric spin echo (aSE) technique was developed to produce uniform, robust fat-water separation in mice at 7T using Iterative Decomposition of Water and Fat with Echo Asymmetry and Least-squares estimation method (IDEAL). The aSE technique had superior image quality as compared to gradient echo IDEAL estimation. Both the spin echo and gradient echo IDEAL techniques resulted in more accura...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiology
دوره 252 2 شماره
صفحات -
تاریخ انتشار 2009