Pulse Doppler ultrasound as a tool for the diagnosis of chronic testicular dysfunction in stallions

نویسندگان

  • Jose M Ortiz-Rodriguez
  • Luis Anel-Lopez
  • Patricia Martín-Muñoz
  • Mercedes Álvarez
  • Gemma Gaitskell-Phillips
  • Luis Anel
  • Pedro Rodríguez-Medina
  • Fernando J Peña
  • Cristina Ortega Ferrusola
چکیده

Testicular function is particularly susceptible to vascular insult, resulting in a negative impact on sperm production and quality of the ejaculate. A prompt diagnosis of testicular dysfunction enables implementation of appropriate treatment, hence improving fertility forecasts for stallions. The present research aims to: (1) assess if Doppler ultrasonography is a good tool to diagnose stallions with testicular dysfunction; (2) to study the relationship between Doppler parameters of the testicular artery and those of sperm quality assessed by flow cytometry and (3) to establish cut off values to differentiate fertile stallions from those with pathologies causing testicular dysfunction. A total of 10 stallions (n: 7 healthy stallions and n: 3 sub-fertile stallions) were used in this study. Two ejaculates per stallion were collected and preserved at 5°C in a commercial extender. The semen was evaluated at T0, T24 and T48h by flow cytometry. Integrity and viability of sperm (YoPro®-1/EthD-1), mitochondrial activity (MitoTracker® Deep Red FM) and the DNA fragmentation index (Sperm Chromatin Structure Assay) were assessed. Doppler parameters were measured at three different locations on the testicular artery (Supratesticular artery (SA); Capsular artery (CA) and Intratesticular artery (IA)). The Doppler parameters calculated were: Resistive Index (RI), Pulsatility Index (PI), Peak Systolic Velocity (PSV), End Diastolic Velocity (EDV), Time Average Maximum Velocity (TAMV), Total Arterial Blood Flow (TABF) and TABF rate. The capsular artery was the most reliable location to carry out spectral Doppler assessment, since blood flow parameters of this artery were most closely correlated with sperm quality parameters. Significant differences in all the Doppler parameters studied were observed between fertile and subfertile stallions (p ≤ 0.05). The principal components analysis assay determined that fertile stallions are characterized by high EDV, TAMV, TABF and TABF rate values (high vascular perfusion). In contrast, subfertile stallions tend to present high values of PI and RI (high vascular resistance). The ROC curves revealed that the best Doppler parameters to predict sperm quality in stallions were: Doppler velocities (PSV, EDV and TAMV), the diameter of the capsular artery and TABF parameters (tissue perfusion parameters). Cut off values were established using a Youden´s Index to identify fertile stallions from stallions with testicular dysfunction. Spectral Doppler ultrasound is a good predictive tool for sperm quality since correlations were determined among Doppler parameters and markers of sperm quality. Doppler ultrasonography could be a valuable diagnostic tool for use by clinical practitioners for the diagnosis of stallions with testicular dysfunction and could be a viable alternative to invasive procedures traditionally used for diagnosis of sub-fertility disorders.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Color Doppler ultrasound evaluation of testicular blood flow in stallions.

The objectives of this study were to evaluate the potential use of color Doppler ultrasound to characterize blood flow to the stallion testis, and to establish reference values for Doppler measures of blood flow in the testicular artery of the stallion. Both testes from each of 52 horses were examined using a pulsed-wave color Doppler ultrasound with a sector array 5/7.5 MHz transducer with a 1...

متن کامل

کاربرد سونوگرافی در هیپرتانسیون پورت

With considerable advances in                     technology, ultrasound, as a noninvasive procedure has been more frequently used for diagnosis of liver diseases and portal hypertension (P.H.). Venography and splenoportography, both are invasive procedures with considerable X-ray exposure. The information obtained from these procedures are limited only to condition of vesseles, while with ultr...

متن کامل

A new ultrasound sign in the diagnosis of pediatric maxillary sinusitis

      Background: Computed tomography scans (CT scan) and X-rays are used to diagnose paediatric maxillary sinusitis. This study aimed at exploring the diagnostic value of the conventional and colour Doppler ultrasounds and their specific findings in cases of paediatric sinusitis.    Methods: A total of 60 children diagnosed with sinusitis were included in this s...

متن کامل

Testicular torsion in a neonate; a case report

The testicular torsion which is typically seen in prepuberty is very rare in the early neonatal period; prenatal diagnosis is difficult. Herein, we report a five day-old male neonate with swelling and erythema of the right scrotum.  Following Doppler ultrasound suggestive of testicular torsion, surgical exploration was undertaken. There was gangrene of the right testis with discoloration and ne...

متن کامل

Carotid doppler ultrasound evaluation in patients with lichen planus

Background: Lichen planus is a chronic inflammatory disease associated with an increased risk of subclinical atherosclerosis and cardiovascular diseases. This study aimed to evaluate patients with lichen planus using carotid Doppler ultrasound parameters.Methods: Forty patients with lichen planus and 40 controls were included in this study. Common carotid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017