Night cooling of the ozonosphere.

نویسنده

  • E H GOWAN
چکیده

Some estimate of the cooling of the ozonosphere can be made using the calculated solar energy absorbed in various layers. After sunset this source of energy is removed and cooling occurs mainly by radiation up and down. The conclusion is reached that during a night the cooling is about 30° C at 50 km. and only a fraction of a degree below 25 km. This means that the ozonosphere temperature inversion around 40 km. will persist throughout the night.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of wind driven ventilative cooling systems for an apartment building in Beijing and Shanghai

This paper presents a performance evaluation of two passive cooling strategies, daytime ventilation and night cooling, for a generic, six-story suburban apartment building in Beijing and Shanghai. The investigation uses a coupled, transient simulation approach to model heat transfer and airflow in the apartments. Wind driven ventilation is simulated using computational fluid dynamics (CFD). Occ...

متن کامل

The Air-Conditioning Energy Savings Achieved by Application of Time- Predicted Driven Night Ventilation

This paper analyses the influence of time-predicted night ventilation applied during the summer season on the total energy consumption of airconditioning system. Analysis has been made on the basis of a computer program for dynamic simulation of air-conditioned rooms thermal behavior. The program was developed at the Department for Thermal Engineering at the Faculty of Mechanical Engineering, U...

متن کامل

A field investigation of passive radiative cooling under Hong Kong’s climate

This paper discusses the feasibility of cooling using radiation under Hong Kong’s hot and humid climate. Three different designs of a passive radiative cooler were studied in this work. The three designs include non-vacuum, and vacuum with seven potassium chloride (KCl) IR-Pass windows as well as one system with a single KCl IR-Pass window. The coolers were examined during daytime and night tim...

متن کامل

Comparative assessment of vernacular passive cooling techniques for improving indoor thermal comfort of modern terraced houses in hot¬タモhumid climate of Malaysia

The main objectives of this study were to investigate vernacular passive cooling techniques and their potential application for improving indoor thermal comfort of naturally ventilated, modern brick terraced houses in Malaysia. Field measurement was conducted in two traditional timber Malay houses and two traditional masonry Chinese shophouses to examine their indoor thermal environments. The r...

متن کامل

Model Selection for Predicting the Return Time from Night Setback

This paper reports a comparison of models for estimating the return time from a night setback condition. Fifty-seven models are compared using simulation data that include the influence of climate, building mass, controller tuning, room orientation, and the unoccupied control strategy on return time. Two-parameter models are recommended for estimating the return time for both heating and coolin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings of the Royal Society of London. Series A, Mathematical and physical sciences

دوره 190 1021  شماره 

صفحات  -

تاریخ انتشار 1947