Oscillometric blood pressure measurement: the methodology, some observations, and suggestions.
نویسندگان
چکیده
Most noninvasive blood pressure (NIBP) devices use the oscillometric method. Published studies of oscillometric methodology introduced varied algorithmic approaches for determination of systolic (SBP), diastolic (DBP), and mean arterial (MAP) blood pressures. While there is a general agreement about MAP determination, controversy exists about the determination of SBP and DBP Accuracy of oscillometric devices has been questioned and validation studies have revealed problems. Several validation protocols have been developed but they are expensive and time consuming to conduct and they have their own limitations. Instruments for bench testing of NIBP devices are useful for some device functions, but they cannot perform dynamic accuracy tests. The issue of accuracy is becoming very important as health care professionals increasingly rely on electronic NIBP devices. The authors developed a compact system for acquisition of NIBP waveforms. Some representative oscillometric waveforms are introduced here to demonstrate the oscillometric method and its shortcomings. A finger photoplethysmograph (PPG) was used to demonstrate a potential improvement of SBP determination. The concept and significance of an oscillometric blood pressure waveform database is introduced and its applications are discussed.
منابع مشابه
Comparison of methods of automatic blood pressure measurement in the same device
Comparison of tacho-oscillographic and oscillometric methods for human blood pressure measurement with cuff occlusion in the same device at the same time is described. For this purpose the measurement system and software for signal processing that realize these methods in the same device was developed. Experiment shows that oscillometric method with photoplethysmographic (PPG) sensors does not ...
متن کاملRapid oscillometric blood pressure measurement compared to conventional oscillometric measurement.
BACKGROUND There have been few reports studying the necessary interval between blood pressure measurements, after the initial rest period. METHODS Blood pressure was measured in 50 patients using the conventional oscillometric technique (COT) and the rapid oscillometric technique (ROT). RESULTS The difference between COT and ROT was -1.1 / -0.1 mmHg, which was not significantly different (p...
متن کاملMonitoring Personalized Trait Using Oscillometric Arterial Blood Pressure Measurements
The blood pressure patterns obtained from a linearly or stepwise deflating cuff exhibit personalized traits, such as fairly uniform peak patterns and regular beat geometry; it can support the diagnosis and monitoring of hypertensive patients with reduced sensitivity to fluctuations in Blood Pressure BP over time. Monitoring of personalized trait in Oscillometric Arterial Blood Pressure Measurem...
متن کاملProspective clinical study to evaluate an oscillometric blood pressure monitor in pet rabbits
BACKGROUND Rabbits are particularly sensitive to develop hypotension during sedation or anaesthesia. Values of systolic or mean non-invasive arterial blood pressure below 80 or 60 mmHg respectively are common under anaesthesia despite an ongoing surgery. A reliable method of monitoring arterial blood pressure is extremely important, although invasive technique is not always possible due to the ...
متن کاملAuthor's response to reviews Title: Oscillometric measure of blood pressure detects association between orthostatic hypotension and depression in population based study of older adults Authors:
Title: Oscillometric measure of blood pressure detects association between orthostatic hypotension and depression in population based study of older adults Author's response to reviews: see over Dear Sir/Madam The authors would like to thank the reviewers for their comments and suggestions with regard to the manuscript entitled 'Oscillometric measure of blood pressure detects association betwee...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedical instrumentation & technology
دوره 39 3 شماره
صفحات -
تاریخ انتشار 2005