Standard versus high-flexion posterior stabilized total knee prostheses.

نویسندگان

  • Ning Li
  • Junwei Li
  • Peng Li
  • Dan Wang
  • Ming Liu
  • Lei Xia
چکیده

This meta-analysis compared clinical outcomes between standard and high-flexion posterior-stabilized total knee prostheses to evaluate which type of total knee prosthesis was superior. Randomized, controlled trials published until October 2013 comparing standard and high-flexion posterior-stabilized total knee prostheses were reviewed. Methodologic quality was assessed with the Physiotherapy Evidence Database scale. After data extraction, the authors compared results with fixed effects or random effects models, depending on the heterogeneity of the included studies. Eight randomized, controlled trials involving 660 patients met the predetermined inclusion criteria. No statistically significant differences between patients undergoing standard and high-flexion posterior-stabilized total knee prostheses were noted in postoperative range of motion (ROM) (weighted mean difference, -1.43; 95% confidence interval [CI], -4.52 to 1.67; P=.37); flexion angle (weighted mean difference, 0.54; 95% CI, -3.75 to 4.84; P=.80); Knee Society Score (weighted mean difference, 0.92; 95% CI, -0.64 to 2.48; P=.25); Hospital for Special Surgery knee score (weighted mean difference, 0.57; 95% CI, -0.42 to 1.55; P=.26); or Knee Society function score (weighted mean difference, 1.00; 95% CI, -1.49 to 3.49; P=.43). No statistical difference was found between the 2 prosthesis types in complications, involving 21 cases in the standard group and 14 cases in the high-flexion group. The current findings confirm that high-flexion posterior-stabilized total knee prostheses are not superior to standard prostheses in terms of ROM, flexion angle, knee scores, or complications with 5 years or less of follow-up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does High-flexion Design of Cruciate Retaining Total Knee Prosthesis Increase Postoperative Range of Motion?

INTRODUCTION: The range of motion (ROM) after total knee arthroplasty (TKA) is one of the most important factors for patient satisfaction, especially in Asian countries. To enhance the knee flexion angle, “highflexion” designs have been introduced in total knee prostheses. One of such design was a new design of femoral prosthesis, which increased the posterior cut on the bone by 2 mm and thicke...

متن کامل

Range of Motion In High Flexion Total Knee Arthroplasty vs. Standard Posterior Stabilized Total Knee Arthroplasty A Prospective, Randomized Study

Range of motion after knee replacement is an important factor in overall outcome. The purpose was to compare motion in patients receiving high flexion prosthesis vs. standard prosthesis. 24 high flexion and standard knee prostheses were used. Patients were followed for two years and evaluated prospectively. The mean HSS was 80.4 for the standard group and 80.7 for the flexion group. At two year...

متن کامل

Evaluation of Postoperative Range of Motion and Functional Outcomes after Cruciate-Retaining and Posterior-Stabilized High-Flexion Total Knee Arthroplasty

PURPOSE The purpose of this study was to compare postoperative range of motion and functional outcomes among patients who received high-flexion total knee arthroplasty using cruciate-retaining (CR-Flex) and posterior-stabilized (PS-Flex) type prostheses. MATERIALS AND METHODS Among 127 patients (186 knees) who underwent high-flexion total knee arthroplasty between 2005 and 2007, 92 knees were...

متن کامل

High-Flexion Posterior-Stabilized Total Knee Prosthesis: Is It Worth the Hype?

High-flexion knee prosthesis was introduced with the aim of obtaining higher degree of flexion and good survivorship in patients with high functional demands or those requiring squatting, kneeling, etc., which is more common in Asians. Based on all the research and experience with this prosthesis, it was concluded that high flexion designs meet the need of deeper degrees of flexion in selected ...

متن کامل

Polyethylene wear particles in synovial fluid after total knee arthroplasty.

The aims of the current study were to examine polyethylene particles in synovial fluid at an early stage, and to compare a newly introduced medial pivot total knee prosthesis with an established posterior-stabilized total knee prosthesis. Synovial fluid was obtained 1 year after knee arthroplasty from 17 patients with well-functioning prostheses (22 knees, 11 posterior-stabilized prostheses and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 38 3  شماره 

صفحات  -

تاریخ انتشار 2015