A treatment planning comparison of volumetric modulated arc therapy and proton therapy for a sample of breast cancer patients treated with post-mastectomy radiotherapy.
نویسندگان
چکیده
Post-mastectomy radiotherapy (PMRT) has been shown to improve disease-free survival and overall survival for locally advanced breast cancer. However, long term survivors may develop life threatening acute and chronic treatment-related toxicities after radiotherapy, like cardiac toxicity and second cancers. The more advanced techniques like volumetric arc therapy (VMAT), and proton therapy have the potential to improve treatment outcome by constraining doses to radiosensitive organs, but evidence from outcome study will not be available until years or decades later. Furthermore, the literature is largely incomplete regarding systematic comparison of potential benefits of advanced technologies for PMRT. The purpose of this study was to compare proton therapy, both passively scattered (PSPT) and intensity modulated (IMPT), to VMAT and develop an evidence-based rationale for selecting a treatment modality for left sided post-mastectomy radiotherapy (PMRT) patients. Eight left-sided PMRT patients previously treated with VMAT were included in this study. Planning target volumes (PTV) included the chest wall and regional lymph nodes. PSPT and IMPT plans were created using a commercial proton treatment planning system. The resulting plans were compared to the corresponding VMAT on the basis of dosimetric and radiobiological endpoints. The uncertainties in risk from proton range, set-up errors, and dose-response models were also evaluated. All modalities produced clinically acceptable treatment plans with nearly 100% tumor control probability. Both proton techniques provided significantly lower normal tissue complication probability values for the heart (p < 0.02) and lung (p < 0.001). Patient-averaged second cancer risk for the contralateral breast and lungs were also significantly lower (p < 0.001) with protons compared to VMAT. The findings of this study were upheld by the uncertainty analysis. All three techniques provided acceptable PMRT treatment plans. Proton therapy showed significant advantages in terms of predicted normal tissue sparing compared to VMAT, taking into account possible uncertainties.
منابع مشابه
Early toxicity of moderate hypofractionated volumetric modulated Arc radiotherapy for localized prostate cancer
Background: Based on the radiation biology model of prostate cancer, hypofractionated radiotherapy can improve the treatment outcomes without increasing toxicity. Although hypofractionated radiotherapy is implemented over a short period of time, it is more convenient and cheaper compared with conventional fractionated treatment. The aim of this study was to investigate the early toxicity of mod...
متن کاملDosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملDosimetric Comparison and Evaluation of Three Radiotherapy Techniques for Use after Modified Radical Mastectomy for Locally Advanced Left-sided Breast Cancer
This study aimed to compare the post-modified radical mastectomy radiotherapy (PMRMRT) for left-sided breast cancer utilizing 3-dimensional conformal radiotherapy with field-in-field technique (3DCRT-FinF), 5-field intensity-modulated radiation therapy (5F-IMRT) and 2- partial arc volumetric modulated arc therapy (2P-VMAT). We created the 3 different PMRMRT plans for each of the ten consecutive...
متن کاملDosimetric comparison for volumetric modulated arc therapy and intensity-modulated radiotherapy on the left-sided chest wall and internal mammary nodes irradiation in treating post-mastectomy breast cancer
BACKGROUND The aim of the study was to evaluate the dosimetric benefit of applying volumetric modulated arc therapy (VMAT) on the post-mastectomy left-sided breast cancer patients, with the involvement of internal mammary nodes (IMN). PATIENTS AND METHODS The prescription dose was 50 Gy delivered in 25 fractions, and the clinical target volume included the left chest wall (CW) and IMN. VMAT p...
متن کاملOptimization of prostate cancer radiotherapy using of a spacer gel, volumetric modulated arc therapy and a single biological organ at risk objective
Background: The aim was to evaluate the benefit of technical advances for treatment planning: introduction of a hydrogel spacer, VMAT (volumetric modulated arc therapy) and a single biological organ at risk objective for the rectum and bladder. Initial standard was a step-and-shoot IMRT (intensity modulated radiotherapy) without a spacer and conventional organ at risk objectives. Material...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of proton therapy
دوره 1 1 شماره
صفحات -
تاریخ انتشار 2015