The sensitivity of [11C]choline PET/CT to localize prostate cancer depends on the tumor configuration.
نویسندگان
چکیده
PURPOSE To evaluate the dependency of the sensitivity of [(11)C]choline positron emission tomography/computed tomography (PET/CT) for detecting and localizing primary prostate cancer (PCa) on tumor configuration in the histologic specimen. EXPERIMENTAL DESIGN Forty-three patients with biopsy-proven PCa were included. They underwent radical prostatectomy within 31 days after [(11)C]choline PET/CT. The transaxial image slices and the histologic specimens were analyzed by comparing the respective slices. Maximum standardized uptake values (SUV(max)) were calculated in each segment and correlated with histopathology. The tumor configuration in the histologic specimen was grouped as: I, unifocal; II, multifocal; III, rind-like shaped; IV, size <5 mm. Data analysis included the investigation of detection of PCa by SUV(max), the assessment of the influence of potential contributing factors on tumor prediction, and the evaluation of whether SUV could discriminate cancer tissue from benign prostate hyperplasia (BPH), prostatitis, HGPIN (high-grade prostate intraepithelial neoplasm), or normal prostate tissue. General estimation equation models were used for statistical analysis. RESULTS Tumor configuration in histology was classified as I in 21 patients, as II in 9, as III in 5, and as IV in 8. The prostate segment involved by cancer is identified in 79% of the patients. SUV(max) was located in the same side of the prostate in 95% of patients. Tumor configuration was the only factor significantly negatively influencing tumor prediction (P < 0.001). PCa-SUV(max) (median SUV(max) = 4.9) was not significantly different from BPH-SUV (median SUV(max) = 4.5) and prostatitis-SUV (median SUV(max) = 3.9), P = 0.102 and P = 0.054, respectively. CONCLUSIONS The detection and localization of PCa in the prostate with [(11)C]choline PET/CT is impaired by tumor configuration. Additionally, in our patient population, PCa tissue could not be distinguished from benign pathologies in the prostate.
منابع مشابه
C-11 Choline and FDG PET/CT Imaging of Primary Cholangiocarcinoma – a Comparative Analysis
Objective(s): This study aimed to compare the diagnostic values of 11C-choline and 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) in patients with cholangiocarcinoma (CCA). Methods: This prospective study was conducted on 10 patients (6 males and 4 females), aged 42-69 years, suspected of having CCA based on CT or magnetic resonance imaging (MRI) resu...
متن کاملImaging, Diagnosis, Prognosis The Sensitivity of [C]Choline PET/CT to Localize Prostate Cancer Depends on the Tumor Configuration
Purpose: To evaluate the dependency of the sensitivity of [C]choline positron emission tomography/ computed tomography (PET/CT) for detecting and localizing primary prostate cancer (PCa) on tumor configuration in the histologic specimen. Experimental Design: Forty-three patients with biopsy-proven PCa were included. They underwent radical prostatectomy within 31 days after [C]choline PET/CT. Th...
متن کاملEvaluation of Prostate Cancer with 11C- and 18F-Choline PET/CT: Diagnosis and Initial Staging.
Early diagnosis and adequate staging are crucial for the choice of adequate treatment in prostate cancer (PC). Morphologic and functional imaging modalities, such as CT and MRI, have had limited accuracy in the diagnosis and nodal staging of PC. Molecular PET/CT imaging with 11C- or 18F-choline-labeled derivatives is increasingly being used, but its role in the diagnosis and initial staging of ...
متن کاملPET/CT for the diagnosis, staging and restaging of prostate cancer
can be used for imaging trabecular changes caused by the metastasis, however, those changes appear relatively late in the course of bone metastases. Therefore, a challenge for imaging prostate cancer is to increase the diagnostic performance. Functional and molecular imaging technologies, such as PET, compared with conventional imaging, offer the possibility to image tumor-specific processes. C...
متن کاملDiagnostic performance of 11C-choline PET/CT and bone scintigraphy in the detection of bone metastases in patients with prostate cancer
The aim of this study was to compare 11C-choline PET/CT and bone scintigraphy (BS) for detection of bone metastases in patients with prostate cancer. Twenty-one patients with histologically proven prostate cancer underwent 11C-choline PET/CT and BS before (n = 4) or after (n = 17) treatment. Patient-, region-, and lesion-based diagnostic performances of bone metastasis of both 11C-choline PET/C...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical cancer research : an official journal of the American Association for Cancer Research
دوره 17 11 شماره
صفحات -
تاریخ انتشار 2011