High-frequency phase shift measurement greatly enhances the sensitivity of QCM immunosensors.
نویسندگان
چکیده
In spite of being widely used for in liquid biosensing applications, sensitivity improvement of conventional (5-20MHz) quartz crystal microbalance (QCM) sensors remains an unsolved challenging task. With the help of a new electronic characterization approach based on phase change measurements at a constant fixed frequency, a highly sensitive and versatile high fundamental frequency (HFF) QCM immunosensor has successfully been developed and tested for its use in pesticide (carbaryl and thiabendazole) analysis. The analytical performance of several immunosensors was compared in competitive immunoassays taking carbaryl insecticide as the model analyte. The highest sensitivity was exhibited by the 100MHz HFF-QCM carbaryl immunosensor. When results were compared with those reported for 9MHz QCM, analytical parameters clearly showed an improvement of one order of magnitude for sensitivity (estimated as the I50 value) and two orders of magnitude for the limit of detection (LOD): 30μgl(-1) vs 0.66μgL(-1)I50 value and 11μgL(-1) vs 0.14μgL(-1) LOD, for 9 and 100MHz, respectively. For the fungicide thiabendazole, I50 value was roughly the same as that previously reported for SPR under the same biochemical conditions, whereas LOD improved by a factor of 2. The analytical performance achieved by high frequency QCM immunosensors surpassed those of conventional QCM and SPR, closely approaching the most sensitive ELISAs. The developed 100MHz QCM immunosensor strongly improves sensitivity in biosensing, and therefore can be considered as a very promising new analytical tool for in liquid applications where highly sensitive detection is required.
منابع مشابه
Detection of two orchid viruses using quartz crystal microbalance (QCM) immunosensors.
Quartz crystal microbalance (QCM) immunosensors are based on the principle that adsorption of substances on the surface of a quartz crystal changes its resonance oscillation frequency. A QCM immunosensor was developed for the detection of both cymbidium mosaic potexvirus (CymMV) and odontoglossum ringspot tobamovirus (ORSV) by pre-coating the QCMs with virus-specific antibodies. Upon binding of...
متن کاملFrequency-shift vs phase-shift characterization of in-liquid quartz crystal microbalance applications.
The improvement of sensitivity in quartz crystal microbalance (QCM) applications has been addressed in the last decades by increasing the sensor fundamental frequency, following the increment of the frequency/mass sensitivity with the square of frequency predicted by Sauerbrey. However, this sensitivity improvement has not been completely transferred in terms of resolution. The decrease of freq...
متن کاملNoise Measurement Setup for Quartz Crystal Microbalance
Quartz crystal microbalance (QCM) is a high sensitive chemical sensor which has found widespread spectrum of applications. There are several mechanisms that are related to fluctuation phenomena. Since the aim of our research is oriented to study the sensitivity and influence of different kind of noises on sensor resolution, we modified an existing method to measure the small frequency fluctuati...
متن کاملDevelopment of a Flow Injection Based High Frequency Dual Channel Quartz Crystal Microbalance
When the quartz crystal microbalance (QCM) is used in liquid for adsorption or desorption monitoring based bio- or chemical sensing applications, the frequency shift is not only determined by the surface mass change, but also by the change of liquid characteristics, such as density and viscosity, which are greatly affected by the liquid environmental temperature. A monolithic dual-channel QCM i...
متن کاملA Novel Metamaterial Microelectromechanical Systems Phase Shifter with High Phase Shift and High Bandwidth
In this paper, new topology of phase shifter is proposed that uses advantage of metamaterial and MEMS technology. The phase shifter is switched between two states of RH- and LH-TL having frequency passband unlike other proposed metamaterials which create the maximum phase shift from one unitcell. Analysis and design approach of the phase shifter is presented and the structure is simulated using...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biosensors & bioelectronics
دوره 65 شماره
صفحات -
تاریخ انتشار 2015