Kangaroo versus freestyle stentless bioprostheses in a juvenile sheep model: hemodynamic performance and calcification behavior.

نویسندگان

  • William M L Neethling
  • Andrew J Hodge
  • Ross Glancy
چکیده

BACKGROUND Glutaraldehyde-preserved bioprosthetic heart valve substitutes have limited performance and longevity due to tissue degeneration and calcification. The Freestyle valve (Medtronic Heart Valves, Inc, Minneapolis, MN) combines zero fixation pressure and proportional, variant-amino oleic acid (AOA) as antidegeneration and antimineralization measures. The aim of this study was to compare the calcification behavior of glutaraldehyde-preserved kangaroo aortic valves with Freestyle stentless bioprostheses in a juvenile sheep model. METHODS Pulmonary artery and valve replacements were performed in juvenile sheep with Freestyle stentless aortic valves (n = 4) or glutaraldehyde-preserved kangaroo stentless aortic valves with no antimineralization measures (n = 6), and explanted at 200 postoperative days. RESULTS Freestyle stentless valves and stentless kangaroo aortic valves showed normal valve function immediately postoperatively and up to 120 days. Valve leaflets of all valves were macroscopically free of visible calcification with normal histology. Valve leaflet calcification (microg Ca/mg tissue) was less in kangaroo than Freestyle (1.27 +/- 0.43 versus 2.38 +/- 1.37, p = 0.856). Aortic wall tissue calcification was severe in kangaroo and Freestyle (127.93 +/- 12.22 versus 122.19 +/- 11.99, p = 0.596). CONCLUSIONS We conclude that glutaraldehyde-preserved kangaroo aortic valve leaflets are equal to AOA-treated Freestyle stentless valve leaflets with regard to calcification in juvenile sheep. Both bioprostheses are prone to aortic wall calcification. The low calcification features of the kangaroo aortic valve leaflets without antimineralization treatment may benefit the longevity of the valve.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of stentless kangaroo aortic valves in the mitral position of juvenile sheep.

BACKGROUND AND AIM OF THE STUDY The performance and longevity of bioprosthetic heart valves are limited by tissue calcification and degeneration after implantation. Experimental valve replacement in large animal models forms an important component of the preclinical evaluation of these bioprosthetic heart valves. The study aim was to assess the feasibility of a mitral model for stentless valves...

متن کامل

Hemodynamic and physical performance during maximal exercise in patients with an aortic bioprosthetic valve: comparison of stentless versus stented bioprostheses.

OBJECTIVES The objective of this study was to compare stentless bioprostheses with stented bioprostheses with regard to their hemodynamic behavior during exercise. BACKGROUND Stentless aortic bioprostheses have better hemodynamic performances at rest than stented bioprostheses, but very few comparisons were performed during exercise. METHODS Thirty-eight patients with normally functioning s...

متن کامل

Performance of stentless versus stented aortic valve bioprostheses in the elderly patient: a prospective randomized trial.

OBJECTIVES Although stentless aortic bioprostheses are believed to offer improved outcomes, benefits remain unsubstantiated. The aim of our study was to compare stentless with stented bioprostheses, with regard to postoperative changes in left ventricular mass and hemodynamic performance, in the elderly patient. METHODS Forty patients with aortic stenoses, over the age of 75 years, were rando...

متن کامل

Stentless aortic valves. Current aspects

The design of stentless valve prostheses is intended to achieve a more physiological flow pattern and superior hemodynamics in comparison to stented valves. First - generation stentless bioprosthesis were the Prima valve, the Freestyle valve and the Toronto stentless porcine valve. The second generation of stentless valves, as the Super stentless aortic porcine valve, need only one suture line....

متن کامل

Structural Valve Deterioration After Aortic Valve Replacement with Medtronic Freestyle Stentless Porcine Aortic Root Bioprostheses

The Medtronic freestyle aortic root bioprosthesis (Medtronic, Inc., Minneapolis, MN, USA) is a stentless valve with an effective orifice area that is larger than that observed on other bioprostheses. However, there have been sporadic reports of structural valve deterioration (SVD), such as aortic root wall rupture, leaflet tearing, and pseudoaneurysm formation. We report five cases of SVD of fr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiac surgery

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 2005