Validation of an open source framework for the simulation of blood flow in rigid and deformable vessels.

نویسندگان

  • T Passerini
  • A Quaini
  • U Villa
  • A Veneziani
  • S Canic
چکیده

We discuss in this paper the validation of an open source framework for the solution of problems arising in hemodynamics. The proposed framework is assessed through experimental data for fluid flow in an idealized medical device with rigid boundaries and a numerical benchmark for flow in compliant vessels. The core of the framework is an open source parallel finite element library that features several algorithms to solve both fluid and fluid-structure interaction problems. The numerical results for the flow in the idealized medical device (consisting of a conical convergent, a narrow throat, and a sudden expansion) are in good quantitative agreement with the measured axial components of the velocity and pressures for three different flow rates corresponding to laminar, transitional, and turbulent regimes. We emphasize the crucial role played by the accuracy in performing numerical integration, mesh, and time step to match the measurements. The numerical fluid-structure interaction benchmark deals with the propagation of a pressure wave in a fluid-filled elastic tube. The computed pressure wave speed and frequency of oscillations, and the axial velocity of the fluid on the tube axis are close to the values predicted by the analytical solution associated with the benchmark. A detailed account of the methods used for both benchmarks is provided.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of Pulsatile Non-Newtonian Blood Flow Through Abdominal Aorta and Renal Arteries Incorporating Fluid- Structure Interaction

Background: The interaction between the blood and the vessel wall is of great clinical interest in studying cardiovascular diseases, the major causes of death in developed countries.Objective: To understand the effects of incorporating fluid-structure interaction into the simulation of blood flow through an anatomically realistic model of abdominal aorta and renal arteries reconstructed from CT...

متن کامل

A Mathematical Model for Blood Flow Through Narrow Vessels with Mild-Stenosis (RESEARCH NOTE)

In this paper we examine the effect of mild stenosis on blood flow, in an irregular axisymmetric artery with oscillating pressure gradient. The Herschel-Bulkley fluid model has been utilized for this study. The combined influence of an asymmetric shape and surface irregularities of constriction has been explored in this computational study. An extensive quantitative analysis has been performed ...

متن کامل

Newtonian and Non-Newtonian Blood Flow Simulation after Arterial Stenosis- Steady State and Pulsatile Approaches

Arterial stenosis, for example Atherosclerosis, is one of the most serious forms of arterial disease in the formation of which hemodynamic factors play a significant role. In the present study, a 3-D rigid carotid artery with axisymmetric stenosis with 75% reduction in cross-sectional area is considered. Laminar blood flow is assumed to have both Newtonian and non-Newtonian behavior (generalize...

متن کامل

PERFORMANCE MODEL AND ANALYSIS OF BLOOD FLOW IN SMALL VESSELS WITH MAGNETIC EFFECTS

In this paper consider a two-fluid model consisting of a core region of suspension of all the erythrocytes (particles) in plasma (fluid) assumed to be a particle-fluid mixture and a peripheral layer of cell-free plasma (Newtonian fluid), has been proposed to represent blood flow in small diameter tubes with effects of magnetic. The analytical results obtained in the proposed model for effective...

متن کامل

Simulation study of Hemodynamic in Bifurcations for Cerebral Arteriovenous Malformation using Electrical Analogy

Background and Objective: Cerebral Arteriovenous Malformation (CAVM) hemodynamic is disease condition, results changes in the flow and pressure level in cerebral blood vessels. Measuring flow and pressure without catheter intervention along the vessel is big challenge due to vessel bifurcations/complex bifurcations in Arteriovenous Malformation patients. The vessel geometry in CAVM patients are...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal for numerical methods in biomedical engineering

دوره 29 11  شماره 

صفحات  -

تاریخ انتشار 2013