Combined Glaucoma Tube Shunt (Ahmed) and Fluocinolone Acetonide (Retisert™) Implantation Compared to Ahmed Alone in Uveitic Glaucoma
نویسندگان
چکیده
INTRODUCTION Glaucoma is a known complication of uveitis, and may require glaucoma tube shunt implantation for intraocular pressure (IOP) control. The success of glaucoma tube shunt implantation in the setting of a local ocular steroid depot in uveitic glaucoma remains unknown. The purpose of this study was to determine whether patients who underwent combined glaucoma tube shunt (Ahmed) and fluocinolone acetonide (Retisert™, Bausch + Lomb, Bridgewater, NJ, USA) implantation have superior outcomes compared to patients with Ahmed implants only in the setting of uveitic glaucoma. METHODS All participants were studied retrospectively and underwent Ahmed implantation alone or with existing/concurrent Retisert implantation (combined group) at a single academic institution. The main outcome measures were IOP, visual acuity (VA), number of IOP-lowering medications, and adverse events at 6 months after Ahmed implantation. Secondary outcome measures included adverse events and surgical success at 6 months after Ahmed implantation. RESULTS Mean IOP at 6 months after Ahmed implantation was 15.3 ± 4.8 and 15.1 ± 4.9 mm Hg in the Ahmed only group (n = 17) and the combined group (n = 17), respectively (p = 0.89). The mean number of IOP-lowering medications at 6 months after Ahmed implantation was 1.7 ± 1.0 and 1.8 ± 1.0 in the Ahmed only group and the combined group, respectively (p = 0.86). Mean VA at 6 months after Ahmed implantation was 0.35 ± 0.29 and 0.42 ± 0.33 log mean angle of resolution in the Ahmed only group and the combined group, respectively (p = 0.50). No significant differences in surgical success or adverse events were noted between the two groups. CONCLUSION At 6 months, no significant differences in mean IOP, mean number of IOP-lowering medications, VA, surgical success, or adverse events were noted between Ahmed implantation alone or combined Ahmed and Retisert implantation in patients with uveitic glaucoma.
منابع مشابه
Improved Surgical Success of Combined Glaucoma Tube Shunt and Retisert® Implantation in Uveitic Eyes: A Retrospective Study
INTRODUCTION The purpose of this study was to determine whether the outcomes following placement of a fluocinolone acetonide implant (Retisert(®); Bausch & Lomb, Inc.) combined with an Ahmed™ glaucoma valve (New World Medical, Inc.) in eyes with uveitic glaucoma (UG Retisert) were different when compared to an Ahmed valve alone in eyes with uveitic glaucoma or primary open angle glaucoma (UG no...
متن کاملCombined posterior chamber intraocular lens, vitrectomy, Retisert, and pars plana tube in noninfectious uveitis.
OBJECTIVE To assess the safety and efficacy of combined cataract extraction, posterior chamber intraocular lens placement, pars plana vitrectomy, fluocinolone acetonide intravitreal implant (Retisert), and Ahmed valves with pars plana tube (CPR-PT) in eyes with chronic, posterior, noninfectious uveitis. METHODS Retrospective study of patients who underwent CPR-PT. Outcome measures included vi...
متن کاملA retrospective study on the outcomes of Ahmed valve versus Ahmed valve combined with fluocinolone implant in uveitic glaucoma.
Purpose To compare the intraocular pressure (IOP) outcomes of Ahmed glaucoma valve (AGV) surgery alone versus AGV with fluocinolone implant in uveitic glaucoma patients. Methods We identified uveitic glaucoma patients with AGV surgery alone and AGV surgery combined with fluocinolone implant from the Massachusetts Eye and Ear Ocular Inflammation Database. Demographic information, visual acuity...
متن کاملSurgical Outcomes of Ahmed or Baerveldt Tube Shunt Implantation for medically Uncontrolled Traumatic Glaucoma
AIM To describe postoperative surgical success of either Ahmed or Baerveldt tube shunt implantation for eyes with medically uncontrolled traumatic glaucoma. MATERIALS AND METHODS A review was carried out to identify patients with traumatic glaucoma that required tube shunt implantation between 2009 and 2015 at Rutgers University in Newark, New Jersey, USA. Seventeen eyes from 17 patients met ...
متن کاملReview of the Ahmed versus Baerveldt study—5-year treatment outcomes
The results from the tube versus trabeculectomy (TVT) study provided the evidence to support the use of aqueous shunt surgery and its increasing popularity in the world. The Ahmed versus Baerveldt (AVB) study, a randomized controlled study, compared the efficacy and safety between two of the most commonly used glaucoma drainage implants. A significant proportion of the participants had failed t...
متن کامل