The calibration of scanning monochromators for the measurement of absolute irradiance.

نویسندگان

  • J J Merrill
  • R Gary Layton
چکیده

Certain approximations commonly used in the absolute calibration of a scanning monochromator are examined in terms of the response of the instrument to a monochromatic input. The absolute irradiance due to any spectral feature in the neighborhood of lambda(0) is commonly computed from the expression W = AB(lambda(0))/H(lambda(0)) where A is the area of the spectral feature as recorded by the monochromator output trace, B(lambda) is the spectral irradiance of a standard source, and H(lambda) is the response of the monochromator to B(lambda) when the monochromator corresponds to wavelength lambda. As an example, approximations used in justifying such calculations are examined and applied to an Ebert 0.5-m monochromator. For the case chosen, the approximation is shown to be valid to an accuracy of 1.5% to 2%, depending upon assumptions made in the calculation. It is found that the most serious error for this example is introduced by changes in the sensitivity of the monochromator over a wavelength interval comparable with that of the spectral feature under investigation. A second source of error is found to be the change in the irradiance of the standard source over a wavelength interval comparable to the instrument resolving power.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Technical guide to Set Up a Spectral Solar Direct Normal Irradiance Permanent Station: Study Area- Hannover, Germany

The spectral Direct Normal Irradiance (SDNI) is a basic radiometric quantity from which many other quantities can be derived. It provides not only information about the spectral and distribution of the direct solar radiation reaching a particular location. Accurate knowledge about the spectral direct irradiance shall enable us to gain new scientific results in the: determination of cloud effect...

متن کامل

Comparison of atmospheric spectral radiance measurements from five independently calibrated systems.

A variety of instruments have been developed over the past 50 years to measure spectral radiance in absolute units at UV and visible wavelengths with high spectral resolution. While there is considerable experience in the measurement of spectral irradiance, less emphasis has been given to the reliable measurement of spectral radiance from ground observations. We discuss the methodology and cali...

متن کامل

Evaluating the Reliability of an Accurate Performance in Tray Columns Using Gamma Ray Scanning Technique

The nondestructive techniques are applied to identify important data from the internal process of distillation towers, process towers, pressure vessels and etc. In recent, the gamma-ray scanning techniques as diagnostic tools for scanning of tray columns, packed columns, storage tanks, level measurement and density measurement of containing materials has been used widely. This paper has tried t...

متن کامل

Calibration of Primary Reference Solar Cells at Kriss

The capability of KRISS, Korea, for the SItraceable calibration of primary reference solar cells according to the IEC standards is presented. The method is based on measurement of absolute spectral irradiance of a solar simulator combined with differential spectral responsivity measurement for spectral mismatch correction. The uncertainty is evaluated to be less than 2 % (k = 2) for short-circu...

متن کامل

Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties

Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 5 11  شماره 

صفحات  -

تاریخ انتشار 1966