On - Line Sea Beam Acoustic Imaging

نویسنده

  • F. V. Pavlicek
چکیده

duce acoustic images of the~seafloor on-line with a Sea Beam multibeam echo-sounder. This ystem uses a stand alone interface between the Sea Beam system and a grey-scale line-scan recorder. The interface is built around a Motorola 68000 microprocessor and has digitizing capabilities. I t digitizes the detected echo signals from each of the 16 preformed beams inside the Sea Beam echo processor as well as the roll information given by the ship's vertical reference. The acoustic data are then roll compensated and combined into a port and a starboard time series. These time series are eventually output in digital format to a line-scan recorder which produces the grey scale acoustic image. Results are discussed for Sea Beam acoustic images of the seafloor and of the Deep Scattering layers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computation of Single Beam Echo Sounder Signal for Underwater Objects Detection and Quantification

Underwater Acoustic methods have been extensively used to locate and identify marine objects. These applications include locating underwater vehicles, finding shipwrecks, imaging sediments and imaging bubble fields. Ocean is fairly transparent to sound and opaque to all other sources of radiation. Acoustics technology is the most effective tool for monitoring this environment because of the sou...

متن کامل

Differential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms

Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...

متن کامل

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

Real-time acoustic tomography system and the experience of Caspian current sea monitoring

The Acoustic Tomography (AT) systems are used to monitor long-term and continuous flow in rivers, seas and oceans. One of the disadvantages of existing systems in Iran is the inability of real-time/automated measurements. In this study, by adding a raspberry Pi computer to the system and performing the required programming, it was possible to do online monitoring. The data are transferred to th...

متن کامل

Two-photon microscopy with simultaneous standard and extended depth of field using a tunable acoustic gradient-index lens.

We describe a simple setup that allows depth of field switching at kilohertz rates in a nonlinear microscope. Beam profile and/or divergence are modulated using a tunable, acoustically driven gradient-index fluid lens. We demonstrate two modulation strategies, one based on fast varifocus scanning during each pixel and the other based on pseudo-Bessel beam excitation. Average beam shape is switc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000