Patient-specific instrumentation for total knee replacement verified by computer navigation: a case report.

نویسندگان

  • Kok-Yu Chan
  • Yee-Hong Teo
چکیده

Patient-specific instrumentation (PSI) enables better restoration of the mechanical axis in total knee replacement (TKR) than conventional instrumentation (alignment guides) does. We verified the accuracy of the PSI by computer navigation. The PSI jigs were accurate only if they were pinned accurately onto the distal femur and proximal tibia. Any slight malposition of the jigs leads to malalignment of the bone cuts. In the absence of computer navigation, the accuracy of the jig alignments cannot be checked and may result in malalignment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation

Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...

متن کامل

Computer-assisted navigation of total knee arthroplasty for osteoarthritis in a patient with severe posttraumatic femoral deformity.

In the setting of extraarticular deformities of the knee, total knee arthroplasty (TKA) is difficult, as anatomical abnormalities obstruct identification of alignment landmarks and may preclude the use of traditional instrumentation. The long-term clinical value of computer assistance for TKA is a point of ongoing controversy. Few reports describe the use of computer-assisted orthopedic surgery...

متن کامل

Surgical navigation in paediatric orthopaedics

Computer-assisted orthopaedic surgery was born in the 1990s. Nowadays, computer-assisted orthopaedic surgery is used for transpedicular screw fixation and for total knee arthroplasty.Patient-specific instrumentation is one type of computer-assisted surgery based on volumetric images, such as computed tomography or magnetic resonance imaging.In this article, possible applications of patient-spec...

متن کامل

Total Knee Replacement in the Obese Patient: Comparing Computer Assisted and Conventional Technique

PURPOSE Obesity is being considered a "global epidemic." Surgical procedures are rendered more difficult in obese patients. We aimed to see whether any benefits were evident with use of computer navigation during total knee replacement in these cases. METHODS A retrospective analysis of 287 TKR performed by a single surgeon was undertaken, including 133 TKR undertaken with computer navigation...

متن کامل

Early Results of Oxford Mobile Bearing Medial Unicompartmental Knee Replacement (UKR) with the Microplasty Instrumentation: An Indian Experience

Background: Oxford medial unicompartmental knee replacement (UKR) is indicated in patients with anteromedialosteoarthritis (AMOA) of the knee. Microplasty (MP) instrumentation was introduced in 2012 as an improvement overphase 3 instrumentation. Advantages of this instrumentation include conservative tibial cut, decreased tibial re-cut rateand improved component alignment. We report the results...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 2012