In vitro biocompatibility evaluation of a novel bicarbonate-buffered amino-acid solution for peritoneal dialysis.

نویسندگان

  • A Jörres
  • G M Gahl
  • K Ludat
  • U Frei
  • J Passlick-Deetjen
چکیده

BACKGROUND Conventional lactate-buffered peritoneal dialysis fluids containing glucose as the osmotic agent have been shown to compromise important peritoneal host defence functions. The current study employed an in vitro model using activated peripheral blood mononuclear leukocytes (PBMC) for the preclinical biocompatibility assessment of a novel bicarbonate-buffered peritoneal dialysis fluid containing 1.0% amino acids as the osmotic agent. METHODS PBMC (5 x 10(6)/ml) were pre-exposed (10-30 mm, 37 degrees C) to bicarbonate-buffered 1% amino-acid solution, bicarbonate- or lactate-buffered 1.5% glucose fluid, or control medium (RPMI). The cells were then washed and stimulated for 2 h at 37 degrees C in RPMI containing 100 ng/ml E.coli endotoxin from strain O55:B5. The cytokines IL-6 and TNF alpha in cell supernatants were assessed using specific enzyme immunoassays, cytokine mRNA expression by reverse transcription polymerase chain reaction. RESULTS Short, i.e. 10 min, exposure to conventional, lactate-buffered glucose fluid resulted in a significant and time-dependent inhibition of cytokine release and mRNA expression by activated PBMC, whereas the cytokine response was improved even following prolonged (up to 2 h) exposure to bicarbonate-buffered 1% amino-acid solution or bicarbonate-buffered 1.5% glucose fluid. CONCLUSIONS Our results suggest that very short, i.e. potentially clinically relevant, exposure to conventional dialysis fluid impairs the cytokine response by activated leukocytes. In this respect, the use of bicarbonate-buffered solutions containing 1.0% amino acids or 1.5% glucose may result in improved biocompatibility properties.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biocompatibility and tolerability of a purely bicarbonate-buffered peritoneal dialysis solution.

BACKGROUND Novel peritoneal dialysis solutions are characterized by a minimal content of glucose degradation products and a neutral pH. Many studies have shown the biocompatibility of neutral lactate-buffered solutions; however, until now, the effect of purely bicarbonate-buffered solutions has not been intensively studied in vivo. METHODS This study was an open label, prospective, crossover ...

متن کامل

Biocompatibility pattern of a bicarbonate/lactate-buffered peritoneal dialysis fluid in APD: a prospective, randomized study.

BACKGROUND In chronic ambulatory peritoneal dialysis, bicarbonate-buffered fluids, with their neutral pH and less advanced glycosylation end-products (AGE) and glucose degradation products (GDP), have better biocompatibility than conventional peritoneal dialysis (PD) solutions. That difference may be more beneficial in automated peritoneal dialysis (APD), due to its more frequent exchanges and ...

متن کامل

Improved in vitro biocompatibility of bicarbonate-buffered peritoneal dialysis fluid.

BACKGROUND Conventional peritoneal dialysis fluids (PDFs) have been shown to damage the mesothelial layer and are associated with the development of peritoneal fibrosis and neoangiogenesis. New-generation PDFs have therefore been developed with physiological pH and reduced levels of glucose degradation products (GDPs), precursors of advanced glycation end products (AGEs). In this work, we evalu...

متن کامل

Biocompatible peritoneal dialysis solutions: do they indeed affect the outcome?

Numerous studies have confirmed beneficial effects of polyglucose dialysis solution (PG-DS), an amino acid dialysis solution (AA-DS), and bicarbonate (bic) or bicarbonate/lactate (bic/lac) buffered solutions on selected components of peritoneal bioavailability or clinical parameters of peritoneal dialysis (PD) patients. Few adverse effects have also been described. A question arises whether the...

متن کامل

Automated peritoneal dialysis with 'on-line'-prepared bicarbonate-buffered dialysate: technique and first clinical experiences.

BACKGROUND Automated peritoneal dialysis (APD) has the possibility of increasing the dialysis efficacy by using higher fill volumes, frequent dialysate exchanges, and tidal techniques. It is then possible to treat patients adequately without residual renal function. The drawbacks of the required high amounts of dialysis solution of up to 30 litres per session are the high costs of lactate-based...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 12 3  شماره 

صفحات  -