Concerning The Simulation Of The Connection Of The No-Load Transmission Lines In High Voltage Networks
نویسندگان
چکیده
This paper describes a Matlab program designed to compute the switching over voltages which appear when no-load high voltage lines are energized. The mathematical models of the high voltage distribution lines are presented also. The Matlab program is applied for the case of the high voltage distribution lines from the 220kV network of the ST Craiova, for which the characteristic parameters are known. INTRODUCTION The values of the switching over voltages appearing when the no-load lines are energized depend on the parameters of the electrical diagram or the equivalent circuit diagram at initial instant. The complexity of the mathematical model depends on the number of characteristics of the switching process and also on the type of electrical diagram used (mono or three phase one). The values of the computed over voltages are very important for the high or very high voltages networks, having the neutral point directly earthed. In this case a mono phase diagram can be used because the processes are analogous to the others phases. Considering the line model with concentrated parameters, the line can be represented by the T or Π quadripole, the resistances being neglected in comparison with the reactance values, as is shown in the Figures 1a and 1b. Figure 1: Equivalent Diagram: a) T Quadripole; b) Π Quadripole Corresponding to the steady state operation at 50Hz, the value of the concentrated parameters can be computed by means the impedances having the following expressions: ⋅ for T quadripol : 2 c Z l L tg λ β = ω ,
منابع مشابه
Fault Locating in High Voltage Transmission Lines Based on Harmonic Components of One-end Voltage Using Random Forests
In this paper, an approach is proposed for accurate locating of single phase faults in transmission lines using voltage signals measured at one-end. In this method, harmonic components of the voltage signals are extracted through Discrete Fourier Transform (DFT) and are normalized by a transformation. The proposed fault locator, which is designed based on Random Forests (RF) algorithm, is train...
متن کاملA New Load-Flow Method in Distribution Networks based on an Approximation Voltage-Dependent Load model in Extensive Presence of Distributed Generation Sources
Power-flow (PF) solution is a basic and powerful tool in power system analysis. Distribution networks (DNs), compared to transmission systems, have many fundamental distinctions that cause the conventional PF to be ineffective on these networks. This paper presents a new fast and efficient PF method which provides all different models of Distributed Generations (DGs) and their operational modes...
متن کاملOptimal Placement and Sizing of Distributed Generations in Unbalanced Distribution Networks Considering Load Models and Uncertainties
Development of distributed generations’ technology, trends in the use of these sources to improve some of the problems such as high losses, low reliability, low power quality and high costs in distributed networks. Choose the correct location to install and proper capacity of these sources, such as important things that must be considered in their use. Since distribution networks are actu...
متن کاملOptimal placement and sizing of distributed generation considering FACTS devices and load uncertainty using hybrid sine-cosine algorithm and particle swarm optimization (HSCA-PSO)
Using Distributed Generation (DG) in electrical distribution networks brings many advantages and thus, optimal placement and sizing of these units become important. Most of the researches in this field neglect the effect of transmission system on distribution section. These researches also ignore the effect of Flexible Alternating Current Transmission Systems (FACTS). This thesis proposes a new...
متن کاملOnline Voltage Stability Monitoring and Prediction by Using Support Vector Machine Considering Overcurrent Protection for Transmission Lines
In this paper, a novel method is proposed to monitor the power system voltage stability using Support Vector Machine (SVM) by implementing real-time data received from the Wide Area Measurement System (WAMS). In this study, the effects of the protection schemes on the voltage magnitude of the buses are considered while they have not been investigated in previous researches. Considering overcurr...
متن کامل