Two cases of parachute tricuspid valve confirmed by three-dimensional echocardiography

نویسندگان

  • Hedieh Alimi
  • Afsoon Fazlinezhad
چکیده

BACKGROUND Parachute tricuspid valve is a rare congenital malformations explained in the literature. In most cases, this malformation coexists with other congenital defects. The importance of this condition depends on its functional consequences. CASE REPORT First case was a 52-year-old female patient presented with palpitation. She had a history of paroxysmal supraventricular tachycardia. Transthoracic echocardiography revealed large secundum type atrial septal defect and all the tricuspid valve leaflets appeared to be connected to a single calcified papillary muscle in right ventricle suggestive of parachute tricuspid valve. Echocardiography showed severe right ventricle and right atrial enlargement, and moderate to severe tricuspid regurgitation without significant tricuspid stenosis. Another case was a 30-year-old female patient referred for echocardiography prior to her breast cancer chemotherapy. Transthoracic echocardiography revealed a right ventricle with an unusual fusion of papillary muscles resulting in a single calcified head for the attachment of all tricuspid leaflets. These findings were suggestive of a parachute-like tricuspid valve. Other data were mild to moderate tricuspid regurgitation without any stenosis, and normal right ventricle size and function. In both cases, parachute tricuspid valve was confirmed by three dimensional echocardiograph. CONCLUSION In our first case, parachute tricuspid valve was associated with atrial septal defect, although in the second case, no associated anomaly was detected, a condition not previously reported in the literature. In both cases, parachute tricuspid valve was not associated with tricuspid stenosis. Based on other published cases, parachute involvement of the tricuspid valve is less often reported than cases involving the mitral valve. Additionally, the associated consequences in tricuspid valve position such as tricuspid stenosis seem to be less significant than cases involving mitral valve. It is recommended that in patients with tricuspid valve involvement, parachute anomaly should be considered as a possible rare cause.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tricuspid Valve Endocarditis in an Intravenous Drug Abuser: A Case Report

Recently, there have been more reports of cardiac valve infections due to the increasing number of intravenous (IV) drug abusers and chronic renal failure patients. Among cardiac valves, tricuspid valve is most commonly affected in the course of endocarditis. Appropriate management of these patients is a challenging and controversial issue in the field of cardiac surgery. Treatment options in s...

متن کامل

Accessory tricuspid valve leaflet in an asymptomatic adult.

A 60-year-old, asymptomatic woman with no relevant cardiac history underwent 2-dimensional transthoracic echocardiography as part of a study protocol. The echocardiogram (Fig. 1) indicated the presence of a large mobile mass on the anterior leaflet of the tricuspid valve without notable regurgitation or obstruction. Electrocardiographic, chest radiographic, and laboratory values were within nor...

متن کامل

Parachute tricuspid valve.

Parachute abnormality of mitral valve frequently occurs with left sided obstructive lesions though occasionally may occur as an isolated lesion. Symptoms depend upon the severity of stenosis and associated lesions. Parachute abnormality of the tricuspid valve has rarely been reported and its association with left to right shunts has not been described so far.

متن کامل

Partial detachment of tricuspid valve annuloplasty ring detected by three-dimensional transesophageal echocardiography

A 45-year-old female patient was admitted to our hospital with shortness of breath and swelling in the leg. Ten months prior to the admission she had undergone mitral valve replacement (31 St. Jude bioprosthesis) and tricuspid valve annuloplasty (33 Medtronic ring) because of carcinoid heart disease. All infective parameters were within the normal limits and no fever was detected. A two-dimensi...

متن کامل

Two dimensional echocardiography and the tricuspid valve. Leaflet definition and prolapse.

The tricuspid valve was studied in 143 subjects using two dimensional echocardiography. The groups studied were 40 normal subjects, 31 patients with mitral valve prolapse, 22 with clinically probable tricuspid valve prolapse, 20 with congestive cardiac failure, and 30 with miscellaneous cardiac conditions but no features of right heart disease. Using multiple views it was possible to record all...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2017