Three-dimensional model for human anterior corneal surface.
نویسندگان
چکیده
The anterior corneal asphericity (Q) with the tangential radius is calculated, and a three-dimensional (3-D) anterior corneal model is constructed. Tangential power maps from Orbscan II are acquired for 66 young adult subjects. The Q-value of each semimeridian in the near-horizontal region is calculated with the tangential radius. Polynomial fitting is used to model the 360-semimeridional variation of Q-values, and to fit the Q-values in the near-vertical region. Furthermore, a customized 3-D anterior corneal model is constructed. The 360-semimeridional variation of Q-values is well fitted with a seventh-degree polynomial function for all subjects. The goodness of fit of the polynomial function was >0.9, and the median value was 0.94. The Q-value distribution of the anterior corneal surface showed bimodal variation. Additionally, the Q-values gradually become less negative from the horizontal to the vertical semimeridians in the four quadrants. The 3-D surface plot of the anterior corneal surface approximated a prolate ellipsoid. Using a method to calculate the Q-value with the tangential radius combined with polynomial fitting, we are able to obtain the Q-value of any semimeridian. Compared with general models, this method generates a complete shape of the anterior corneal surface using asphericity.
منابع مشابه
Three-dimensional simulation of human teeth and its application in dental education and research
Background: A comprehensive database, comprising geometry and properties of human teeth, is needed for dentistry education and dental research. The aim of this study was to create a three-dimensional model of human teeth to improve the dental E-learning and dental research. Methods: In this study, a cross-section picture of the three-dimensional model of the teeth was used. CT-Scan im...
متن کامل3D Corneal Shape After Implantation of a Biosynthetic Corneal Stromal Substitute.
PURPOSE The current and projected shortage of transplantable human donor corneas has prompted the development of long-term alternatives to human donor tissue for corneal replacement. The biosynthetic stromal substitutes (BSS) characterized herein represent a potentially safe alternative to donor organ transplantation for anterior corneal stromal diseases. The goal of this phase 1 safety study w...
متن کاملThree-Dimensional Construction of a Rabbit Anterior Corneal Replacement for Lamellar Keratoplasty
The aim of this study was to construct a rabbit anterior corneal replacement for transplantation using acellular porcine corneal matrix (APCM) and rabbit epithelial or stromal cells. APCM was prepared from fresh porcine cornea treated with 0.5% (wt./vol.) sodium dodecyl sulfate (SDS) solution. The expanded stromal cells were first injected into APCM parallel to its surface and were cultured in ...
متن کاملRisk Factors for Failure of Keratoplasty in Keratoconus: Penetrating vs. Deep Anterior Lamellar Keratoplasty
Purpose: To determine the etiologic factors on rejection and failure rates and ocular surface changes after corneal transplantation by either DALK or PKP, in cases of keratoconus (KCN). Methods: In this cross-sectional study, considering the existing data, patients with keratoconus referring to Labbafinejad Medical Center from 2006 to 2016, who underwent corneal transplantation, were enrolled a...
متن کاملCollagenase-mediated tissue modeling of corneal ectasia and collagen cross-linking treatments.
PURPOSE Corneal collagen cross-linking (CXL) is a method for modifying the natural history of keratoconus and other corneal ectatic diseases. The authors evaluated the use of collagenase for generating an experimental model of ectasia to evaluate the topographic effects of CXL interventions. METHODS Nine human corneoscleral specimens unsuitable for transplantation were used. After epithelial ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 18 6 شماره
صفحات -
تاریخ انتشار 2013