Can three-dimensional patient-specific cutting guides be used to achieve optimal correction for high tibial osteotomy? Pilot study.

نویسندگان

  • M Munier
  • M Donnez
  • M Ollivier
  • X Flecher
  • P Chabrand
  • J-N Argenson
  • S Parratte
چکیده

INTRODUCTION Treatment of medial tibiofemoral osteoarthritis with a high-tibial osteotomy (HTO) is most effective when the optimal angular correction is achieved. However, conventional instrumentation is limited when multiplanar correction is needed. HYPOTHESIS Use of patient-specific cutting guides (PSCGs) for HTO provides an accurate correction (difference<2°) relative to the preoperative planning. MATERIALS AND METHODS Between February 2014 and February 2015, 10 patients (mean age: 46 years [range: 31-59]; grade 1 or 2 osteoarthritis in Ahlbäck's classification) were included prospectively in this reliability and safety study. All patients were operated using the same medial opening-wedge osteotomy technique. Preoperative planning was based on long-leg radiographs and CT scans with 3D reconstruction. The PSGCs were used to align the osteotomy cut and position the screw holes for the plate. The desired correction was achieved in the three planes when the holes on the plate were aligned with the holes drilled based on the PSCG. Preoperatively, the mean HKA angle was 171.9° (range: 166-179°), the mean proximal tibial angle was 87° (86-88°) and the mean tibial slope was 7.8° (1-22°). The postoperative correction was compared to the planned correction using 3D CT scan transformations. Intraoperative and postoperative complications were assessed at a minimum follow-up of 1 year. RESULTS The procedure was successfully carried out in all patients with the PSCGs. On postoperative long-leg radiographs, the mean HKA was 182.3° (180-185°); on the CT scan, the mean tibial mechanical angle was 94° (90-98°) and the mean tibial slope was 7.1° (4-11°). In 19 out of 20 postoperative HKA and slope measurements, the difference between the planned and achieved correction was <2° based on the 3D analysis of the three planes in space; in the other case, the slope was 13° instead of the planned 10°. The intra-class correlation coefficients between the postoperative and planned parameters were 0.98 [0.92-0.99] for the HKA and 0.96 [0.79-0.99] for the tibial slope. There were no surgical site infections; one patient had a postoperative hematoma that resolved spontaneously. DISCUSSION The results of this study showed that use of PSCGs in HTO procedures helps to achieve optimal correction in a safe and reliable manner. LEVEL OF EVIDENCE IV - Prospective cohort study.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional postoperative accuracy of extra-articular forearm osteotomies using CT-scan based patient-specific surgical guides

BACKGROUND Computer assisted corrective osteotomy of the diaphyseal forearm and the distal radius based on computer simulation and patient-specific guides has been described as a promising technique for accurate reconstruction of forearm deformities. Thereby, the intraoperative use of patient-specific drill and cutting guides facilitate the transfer of the preoperative plan to the surgery. Howe...

متن کامل

Unicompartmental Knee Osteoarthritis (UKOA): Unicompartmental Knee Arthroplasty (UKA) or High Tibial Osteotomy (HTO)?

  Background: The aim of this review article is to analyze the results of high tibial osteotomy compared to unicompartmental knee arthroplasty in patients with unicompartmental knee osteoarthritis.   Methods: The search engine used was PubMed. The keywords were: "high tibial osteotomy versus unicompartmental knee arthroplasty". Twenty-one articles were found on 28 February 2015, but only eighte...

متن کامل

High tibial osteotomy for the treatment of unicompartmental arthritis of the knee.

Knee axial deformities associated with medial or lateral compartment osteoarthritis can be reliably addressed with high tibial osteotomies. Different surgical techniques can be successfully used for achieving the correction. Whatever the technique used, accurate patient selection and precise surgical procedure are critical to the success of the operation. The authors believe that proximal tibia...

متن کامل

Clinical Outcome of Total Knee Arthroplasty Performed Using Patient-Specific Cutting Guides

BACKGROUND Patient-specific instruments have recently gained attention for ensuring the accuracy of osteotomy and correct alignment in total knee arthroplasty (TKA). We aimed to report our experience with TKA performed by using CT-based 3D model of cutting guides in our clinic. MATERIAL AND METHODS A total of 36 patients (mean age, 67.58±8.46 years; 24 females, 12 males) who underwent TKA with ...

متن کامل

A Surgical Planning and Guidance System for High Tibial Osteotomies

OBJECTIVE To develop a three-dimensional pre-surgical planner and an intraoperative guidance system for high tibial osteotomy. The parameters that describe the placement and orientation of the osteotomy resection planes were to be transmitted to an accompanying guidance system that allowed the surgeon to reproducibly perform the planned procedure. MATERIALS AND METHODS The planning system and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Orthopaedics & traumatology, surgery & research : OTSR

دوره 103 2  شماره 

صفحات  -

تاریخ انتشار 2017