Validity and Reliability of Fitbit Flex for Step Count, Moderate to Vigorous Physical Activity and Activity Energy Expenditure

نویسندگان

  • Ashleigh Sushames
  • Andrew Edwards
  • Fintan Thompson
  • Robyn McDermott
  • Klaus Gebel
چکیده

OBJECTIVES To examine the validity and reliability of the Fitbit Flex against direct observation for measuring steps in the laboratory and against the Actigraph for step counts in free-living conditions and for moderate-to-vigorous physical activity (MVPA) and activity energy expenditure (AEE) overall. METHODS Twenty-five adults (12 females, 13 males) wore a Fitbit Flex and an Actigraph GT3X+ during a laboratory based protocol (including walking, incline walking, running and stepping) and free-living conditions during a single day period to examine measurement of steps, AEE and MVPA. Twenty-four of the participants attended a second session using the same protocol. RESULTS Intraclass correlations (ICC) for test-retest reliability of the Fitbit Flex were strong for walking (ICC = 0.57), moderate for stair stepping (ICC = 0.34), and weak for incline walking (ICC = 0.22) and jogging (ICC = 0.26). The Fitbit significantly undercounted walking steps in the laboratory (absolute proportional difference: 21.2%, 95%CI 13.0-29.4%), but it was more accurate, despite slightly over counting, for both jogging (6.4%, 95%CI 3.7-9.0%) and stair stepping (15.5%, 95%CI 10.1-20.9%). The Fitbit had higher coefficients of variation (Cv) for step counts compared to direct observation and the Actigraph. In free-living conditions, the average MVPA minutes were lower in the Fitbit (35.4 minutes) compared to the Actigraph (54.6 minutes), but AEE was greater from the Fitbit (808.1 calories) versus the Actigraph (538.9 calories). The coefficients of variation were similar for AEE for the Actigraph (Cv = 36.0) and Fitbit (Cv = 35.0), but lower in the Actigraph (Cv = 25.5) for MVPA against the Fitbit (Cv = 32.7). CONCLUSION The Fitbit Flex has moderate validity for measuring physical activity relative to direct observation and the Actigraph. Test-rest reliability of the Fitbit was dependant on activity type and had greater variation between sessions compared to the Actigraph. Physical activity surveillance studies using the Fitbit Flex should consider the potential effect of measurement reactivity and undercounting of steps.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The validity of consumer-level, activity monitors in healthy adults worn in free-living conditions: a cross-sectional study

BACKGROUND Technological advances have seen a burgeoning industry for accelerometer-based wearable activity monitors targeted at the consumer market. The purpose of this study was to determine the convergent validity of a selection of consumer-level accelerometer-based activity monitors. METHODS 21 healthy adults wore seven consumer-level activity monitors (Fitbit One, Fitbit Zip, Jawbone UP,...

متن کامل

Systematic review of the validity and reliability of consumer-wearable activity trackers

BACKGROUND Consumer-wearable activity trackers are electronic devices used for monitoring fitness- and other health-related metrics. The purpose of this systematic review was to summarize the evidence for validity and reliability of popular consumer-wearable activity trackers (Fitbit and Jawbone) and their ability to estimate steps, distance, physical activity, energy expenditure, and sleep. ...

متن کامل

Measuring Heart Rate in Manual Wheelchair Users during Exercise and Free-living Activity with the latest Fitbit Surge Monitor

Researchers have been validating the off-the-shelf activity monitors and customizing devices to help manual wheelchair users (MWUs) objectively monitor their daily physical activity (PA), a critical factor in optimizing health and function. Some of these devices track heart rate (HR) and use it to predict energy expenditure (EE). The validity of these monitors in predicting EE depends on the ac...

متن کامل

Validity of FitBit, Jawbone UP, Nike+ and other wearable devices for level and stair walking.

BACKGROUND Increased physical activity can provide numerous health benefits. The relationship between physical activity and health assumes reliable activity measurements including step count and distance traveled. This study assessed step count and distance accuracy for Nike+ FuelBand, Jawbone UP 24, Fitbit One, Fitbit Flex, Fitbit Zip, Garmin Vivofit, Yamax CW-701, and Omron HJ-321 during leve...

متن کامل

Reliability and validity of ten consumer activity trackers

BACKGROUND Activity trackers can potentially stimulate users to increase their physical activity behavior. The aim of this study was to examine the reliability and validity of ten consumer activity trackers for measuring step count in both laboratory and free-living conditions. METHOD Healthy adult volunteers (n = 33) walked twice on a treadmill (4.8 km/h) for 30 min while wearing ten differe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016