Comparison between Dawson, Trick, and Litzkow electrode and contact lens electrodes used in clinical electroretinography.

نویسندگان

  • M Kuze
  • Y Uji
چکیده

PURPOSE To determine the reliability of the Dawson, Trick, and Litzkow (DTL) electrode in electroretinographic recordings (ERG) in subjects of all ages, we evaluated ERG responses obtained with the contact lens (CL) and DTL electrodes and estimated a DTL/CL ratio for each sample. METHODS Seventy-nine volunteers aged 2-84 years (79 normal eyes) were recruited for the study. Electroretinographic recordings elicited by monocular single-flash stimuli delivered by an automatic ERG recording system were recorded using both CL and the DTL electrodes (CL-ERG and DTL-ERG, respectively). RESULTS The relative amplitude of the DTL-ERG to the CL-ERG was 79.6-99.8% (mean = 93.4%) for the a-wave and 84.4-106.3% (mean = 92.3%) for the b-wave. The relative latency of the DTL-ERG to the CL-ERG was 86. 0-107.6% (mean = 98.2%) for the a-wave and 96.1-113.0% (mean = 97. 9%) for the b-wave. The a- and b-wave amplitudes differed significantly between DTL and CL electrodes only in the 40- to 49-year-old age groups (P <.05). Regression analysis indicated moderate to strong relationships between the electrodes for amplitude (a-wave, r = 0.690; b-wave, r = 0.824) and latency (a-wave, r = 0.667; b-wave, r = 0.725). CONCLUSION The DTL electrode has as high stability as the conventional CL electrodes for ERG recordings in most age groups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrode comparison in pattern electroretinography.

In recent years, there has been great interest in recording the pattern electroretinogram (PERG) in glaucomatous and diabetic populations. The Dawson, Trick, and Litzkow thread electrode (DTLTE) and the gold foil electrode (GFE), commonly used for recording PERGs, were compared for variations in amplitude of response, test-retest variability, and patient comfort. Two study centers collected dat...

متن کامل

Efficient De-colorization of Methylene Blue by Electro-coagulation Method: Comparison of Iron and Aluminum Electrode

In this study, removal of methylene blue by electro-coagulation method using aluminum and iron electrodes was investigated. The influence of the operating parameters such as contact time, current density, anode type, inter-electrodes distance, initial and final pH and energy consumption rate was determined. Dye removal was increased with increases in solution pH, current density and c...

متن کامل

Evaluation of different recording parameters to establish a standard for flash electroretinography in rodents

Different electrodes and stimulus protocols commonly used for electroretinography in rodent eyes were compared for convenience of use, degree of damage to corneal epithelium, and for magnitude of amplitude, reproducibility, left versus right eye accuracy, and reliability of recorded parameters of the flash electroretinogram (ERG). Adult C57BL/6 pigmented mice and albino Wistar rats were used to...

متن کامل

Electroretinograms from noncorneal electrodes.

A. lthough it has long been known that retinal action currents are present, the electroretinogram (ERG) has not become the subject of detailed investigation in the human until recent years. Before Riggs demonstrated that the response might be easily recorded from an electrode supported by a contact lens, no satisfactory method for continuous recording from the human was available. This techniqu...

متن کامل

Multifocal electroretinogram in adults and children with myopia.

OBJECTIVE To determine the correlation between multifocal electroretinogram (mfERG) parameters and the severity of myopia in adults and children. DESIGN Observational study. METHODS Multifocal electroretinograms were recorded using the VERIS system from randomly selected eyes of 104 children and 31 adults with various degrees of myopia. Dawson, Trick, and Litzkow fiber electrodes were used ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Japanese journal of ophthalmology

دوره 44 4  شماره 

صفحات  -

تاریخ انتشار 2000