Scrub the hub! Catheter needleless port decontamination.

نویسندگان

  • Justin L Lockman
  • Eugenie S Heitmiller
  • Judith A Ascenzi
  • Ivor Berkowitz
چکیده

T HE central venous catheter (CVC) is an essential tool in the care of critically ill and high-risk intraoperative patients. Catheterrelated bloodstream infection (CR-BSI) related to CVC insertion technique has been greatly reduced by the use of preventive protocols. However, late CR-BSI remains a significant threat to patient safety and healthcare cost containment. Appropriate CVC maintenance may be the most important factor in the prevention of late CR-BSI. Even transient improper CVC maintenance (e.g., with perioperative drug administration) may cause life-threatening CR-BSI. We examined the effect of scrub duration on macroscopic contamination of needleless CVC connector hubs to illustrate the importance of hub cleaning. We applied commercially available fluoresceine-impregnated powder (Brevis Corporation, Salt Lake City, UT) to CVC hubs and subsequently scrubbed the hubs with 70% isopropyl alcohol pads for 0 (control), 5, 10, and 15 s. Using ultraviolet light, we exposed residual fluorescent powder on the CVC hub. We found a direct relationship between scrub duration and powder contamination, particularly in areas with complex 3-dimensional topography. The correlation between this finding and the incidence of bacterial contamination is unclear, although Menhay has previously questioned the efficacy of a 3–5 s alcohol scrub for heavily contaminated CVC hubs. Anesthesiologists are encouraged to follow best-practice guidelines for CVC maintenance, including attention to disinfection of CVC hubs with isopropyl alcohol pads before syringe or infusion tubing connection. Future studies are needed to determine whether increasing scrub duration will also reduce bacterial colonization and CR-BSI outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of alcohol-impregnated port protectors and needleless neutral pressure connectors on central line-associated bloodstream infections and contamination of blood cultures in an inpatient oncology unit.

BACKGROUND A major risk factor for the development of bloodstream infection is the presence of a central venous catheter (CVC), especially in immunocompromised patients. CVC hub contamination is a risk factor for central line-associated bloodstream infection (CLABSI). METHODS This observational before-after trial in a tertiary care hospital's oncology unit included adult patients with a CVC. ...

متن کامل

Cultures of Needleless Connectors Are Useful for Ruling Out Central Venous Catheter Colonization.

Semiquantitative cultures of skin surrounding intravascular catheter entry sites and catheter hubs have high negative predictive values for catheter tip colonization. However, culturing samples from the inner side of the hub requires the catheter to be manipulated, thus increasing the risk of migration of microorganisms into the bloodstream. Today, hubs are closed using needleless connectors (N...

متن کامل

A needleless closed system device (CLAVE) protects from intravascular catheter tip and hub colonization: a prospective randomized study.

Hub colonization and subsequent intraluminal progression due to frequent opening and manipulation of intravenous systems is the cause of many catheter-related infections (CRI). A prospective, comparative, randomized study was performed to assess a new closed-needleless hub device (CLAVE) compared with conventional open systems (COS). End-points were hub and skin colonization, catheter tip colon...

متن کامل

Continuous passive disinfection of catheter hubs prevents contamination and bloodstream infection.

BACKGROUND Catheter hub decontamination requires a thorough scrub and compliance varies. This study evaluates the effectiveness of a disinfection cap with 70% alcohol in preventing contamination/infection. METHODS A 3-phased, multifacility, quasi-experimental study of adult patients with central lines divided into P1 (baseline), when the standard scrub was used; P2, when the cap was used on a...

متن کامل

Alcohol Caps or Alcohol Swabs With and Without Chlorhexidine: An In Vitro Study of 648 Episodes of Intravenous Device Needleless Connector Decontamination.

The incidence of central venous access device (CVAD)–associated bloodstream infection (CABSI) has been reported to be as high as 21%. Inadequate needleless connector decontamination can result in microbial contamination of the CVAD internal lumen, resulting in device colonization and CABSI. Guidelines vary in recommendations for antiseptic type and duration of application to needleless connecto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 114 4  شماره 

صفحات  -

تاریخ انتشار 2011