Unusual mediastinal lymph node uptake and peritoneopleural fistula demonstrated on Technetium-99m macro-aggregated human serum albumin (Tc-99m MAA) peritoneal scintigraphy in a patient with portal hypertension.
نویسندگان
چکیده
Peritoneal radionuclide scan is an established imaging modality for evaluating peritoneopleural communications. In this case report, unusual mediastinal lymph node radiotracer uptake is seen in a patient with portal hypertension on peritoneal scintigraphy. This was suspected to be due to marked lymphatic enlargement from longstanding portal hypertension since childhood, permitting passage of the large Tc-99m MAA particle. The nodes were morphologically benign on CT. Mediastinal lymph node uptake on peritoneal scintigraphy is rare but should not raise undue clinical concern, particularly in a patient with chronic portal hypertension. Anatomic correlation with SPECT-CT can provide reassurance.
منابع مشابه
Diagnosis of Peritoneopleural Communication with Tc-MAA Scintigraphy in a Patient with Continuous Ambulatory Peritoneal Dialysis: A Case Report and Literature Review
Received 9/18/2003; revised 11/20/2003; accepted 11/25/2003. For correspondence or reprints contact: Ching-Yuan Chen, M.D., Department of Nuclear Medicine, Tri-Service General Hospital, 325 Section 2, Cheng-Kung Road, Taipei 114, Taiwan, ROC. Tel: (886)2-87927121, Fax: (886)2-87927217, Email: [email protected] Continuous ambulatory peritoneal dialysis (CAPD) is an effective therapy for end...
متن کاملHydrothorax in continuous ambulatory peritoneal dialysis: therapeutic implications of Tc-99m MAA peritoneal scintigraphy.
Key words: continuous ambulatory peritoneal dialysis confirmed a massive left-sided pleural effusion (Figure 1a). The echocardiogram revealed concentric (CAPD); end-stage renal disease (ESRD); hydro-thorax; Tc-99m macroaggregated human albumin left ventricular hypertrophy with adequate global performance , and no pericardial effusion. The abdominal (MAA) peritoneal scintigraphy sonogram showed ...
متن کاملEvaluation of persistence of ductus venosus with tc-99m DTPA galactosyl human serum albumin liver scintigraphy and I-123 iodoamphetamine per-rectal portal scintigraphy.
Tc-99m DTPA galactosyl human serum albumin (Tc-99m GSA) hepatic scintigraphy was performed in two patients with patent ductus venosus before and after operation. To evaluate the portosystemic shunt flow, per-rectal portal scintigraphy with I-123 N-isopropyl-p-iodoamphetamine (IMP) was undergone in the same period. The portosystemic shunt indices (PSS index) were decreased from 67.9% to 7.3% in ...
متن کاملLower limb deep vein thrombosis in patients with suspected pulmonary embolism detected with (99m)Tc-MAA simultaneously with lung perfusion scan.
The aim of this study was to evaluate the incidence of deep vein thrombosis (DVT) in patients with suspected pulmonary embolism (PE) and the relation between PE and the site of DVT by using technetium-99m-macroaggregated human serum albumin ((99m)Tc-MAA) radionuclide venography (RNV). Technetium-99m-MAA RNV was performed simultaneously with lung perfusion scintigraphy in 123 patients with s...
متن کاملCourse before and after percutaneous transhepatic portal vein embolization of a patient with cholangiocarcinoma monitored by scintigraphy with Tc-99m galactosyl human serum albumin.
Percutaneous transhepatic portal vein embolization (PTPE) causes atrophy of the embolized lobe and compensatory hypertrophy of the nonembolized lobe, and improves the safety of hepatectomy. We report a patient with cholangiocarcinoma who underwent embolization of both anterior and posterior branches of the right portal vein before hepatectomy. Scintigraphy with Tc-99m galactosyl human serum alb...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Medical journal of Malaysia
دوره 71 2 شماره
صفحات -
تاریخ انتشار 2016