Pii: S0730-725x(01)00410-6

نویسندگان

  • Nobuaki Ishida
  • Hiroyuki Takano
  • Shigehiro Naito
  • Seiichiro Isobe
  • Kunihiko Uemura
  • Tomoyuki Haishi
  • Katsumi Kose
  • Mika Koizumi
  • Hiromi Kano
چکیده

The architecture of baked breads made of fresh dough and frozen dough was depicted by magnetic resonance imaging (MRI). Pieces of bread (16 mm cubic cakes) were soaked in organic solvents containing various concentrations of heavy metals (Cu, Co and Fe) and images of the grain structure of the breads were obtained. Of the organic solvents tested, acetone was preferable because of its single peak that prevents chemical shift effects on images, the retention of the bread structure, and the solubility of heavy metals. The heavy metals, especially Fe, shortened the overly long relaxation times of acetone to practical lengths for imaging and stained the materials to provide high contrasts. The images obtained in acetone with 8 mM Fe were suitable for analyzing crumb grain structures. The bread of fresh dough showed a uniform distribution of pores of various sizes made of thin gluten sheets, whereas the pores in the bread of frozen dough were less, prominently large, non-uniformly distributed, and made of thick gluten sheets. © 2001 Elsevier Science Inc. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pii: S0730-725x(01)00428-3

The subtle signal changes in functional magnetic resonance imaging (fMRI) can be easily overwhelmed by noise of various origins. Spikes in the collected fMRI raw data often arise from high-duty usage of the scanner hardware and can introduce significant noise in the image and thereby in the image time series. Consequently, the spikes will corrupt the functional data and degrade the result of fu...

متن کامل

Pii: S0730-725x(01)00436-2

Functional MRI (fMRI) studies designed for simultaneously measuring Blood Oxygenation Level Dependent (BOLD) and Cerebral Blood Flow (CBF) signal often employ the standard Flow Alternating Inversion Recovery (FAIR) technique. However, some sensitivity is lost in the BOLD data due to inherent T1 relaxation. We sought to minimize the preceding problem by employing a modified UN-inverted FAIR (UNF...

متن کامل

Pii: S0730-725x(01)00393-9

Electric Current Density Imaging (CDI) is a new modality of magnetic resonance imaging that enables electric current distribution imaging in conductive samples containing water. So far, two CDI techniques have been in use: DC-CDI operating at zero frequency and RF-CDI operating at the RF Larmor frequency. In this paper we present a new CDI technique, which extends the CDI frequency range to alt...

متن کامل

Pii: S0730-725x(01)00404-0

In this work, computational methods were utilized to optimize the field produced by the transverse electromagnetic (TEM) resonator in the presence of the human head at 8 Tesla. Optimization was achieved through the use of the classical finite difference time domain (FDTD) method and a TEM resonator loaded with an anatomically detailed human head model with a resolution of 2 mm 2 mm 2 mm. The he...

متن کامل

Pii: S0730-725x(01)00419-2

With the increasing interest in phased arrays in magnetic resonance imaging, imaging system receivers capable of acquiring larger number of parallel signals are needed. Suggested techniques for rapid imaging propose the use of arrays with as many as 128 elements. While simply duplicating the number of receiver chains as needed is a viable technique, it quickly becomes both cumbersome and expens...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001