Normothermic Perfusion in the Assessment and Preservation of Declined Livers Before Transplantation: Hyperoxia and Vasoplegia—Important Lessons From the First 12 Cases

نویسندگان

  • Christopher J.E. Watson
  • Vasilis Kosmoliaptsis
  • Lucy V. Randle
  • Alexander E. Gimson
  • Rebecca Brais
  • John R. Klinck
  • Mazin Hamed
  • Anastasia Tsyben
  • Andrew J. Butler
چکیده

BACKGROUND A program of normothermic ex situ liver perfusion (NESLiP) was developed to facilitate better assessment and use of marginal livers, while minimizing cold ischemia. METHODS Declined marginal livers and those offered for research were evaluated. Normothermic ex situ liver perfusion was performed using an erythrocyte-based perfusate. Viability was assessed with reference to biochemical changes in the perfusate. RESULTS Twelve livers (9 donation after circulatory death [DCD] and 3 from brain-dead donors), median Donor Risk Index 2.15, were subjected to NESLiP for a median 284 minutes (range, 122-530 minutes) after an initial cold storage period of 427 minutes (range, 222-877 minutes). The first 6 livers were perfused at high perfusate oxygen tensions, and the subsequent 6 at near-physiologic oxygen tensions. After transplantation, 5 of the first 6 recipients developed postreperfusion syndrome and 4 had sustained vasoplegia; 1 recipient experienced primary nonfunction in conjunction with a difficult explant. The subsequent 6 liver transplants, with livers perfused at lower oxygen tensions, reperfused uneventfully. Three DCD liver recipients developed cholangiopathy, and this was associated with an inability to produce an alkali bile during NESLiP. CONCLUSIONS Normothermic ex situ liver perfusion enabled assessment and transplantation of 12 livers that may otherwise not have been used. Avoidance of hyperoxia during perfusion may prevent postreperfusion syndrome and vasoplegia, and monitoring biliary pH, rather than absolute bile production, may be important in determining the likelihood of posttransplant cholangiopathy. Normothermic ex situ liver perfusion has the potential to increase liver utilization, but more work is required to define factors predicting good outcomes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful transplantation of porcine liver grafts following 48-hour normothermic preservation

Current cold storage organ preservation technique fails to preserve marginal donor grafts sufficiently. Evidence from large animal experiments suggests superiority of normothermic machine preservation of liver allografts. Long-term organ preservation using normothermic perfusion might not only allow organ viability assessment before transplantation, but also provide the means for further organ ...

متن کامل

Ex Situ Normothermic Machine Perfusion of Donor Livers.

In contrast to conventional static cold preservation (0-4 °C), ex situ machine perfusion may provide better preservation of donor livers. Continuous perfusion of organs provides the opportunity to improve organ quality and allows ex situ viability assessment of donor livers prior to transplantation. This video article provides a step by step protocol for ex situ normothermic machine perfusion (...

متن کامل

From “Gut Feeling” to Objectivity: Machine Preservation of the Liver as a Tool to Assess Organ Viability

Purpose of Review The purpose of this review was to summarise how machine perfusion could contribute to viability assessment of donor livers. Recent Findings In both hypothermic and normothermic machine perfusion, perfusate transaminase measurement has allowed pretransplant assessment of hepatocellular damage. Hypothermic perfusion permits transplantation of marginal grafts but as yet has not...

متن کامل

Liver Transplantation After Ex Vivo Normothermic Machine Preservation: A Phase 1 (First-in-Man) Clinical Trial.

The number of donor organs suitable for liver transplantation is restricted by cold preservation and ischemia-reperfusion injury. We present the first patients transplanted using a normothermic machine perfusion (NMP) device that transports and stores an organ in a fully functioning state at 37°C. In this Phase 1 trial, organs were retrieved using standard techniques, attached to the perfusion ...

متن کامل

Criteria for Viability Assessment of Discarded Human Donor Livers during Ex Vivo Normothermic Machine Perfusion

Although normothermic machine perfusion of donor livers may allow assessment of graft viability prior to transplantation, there are currently no data on what would be a good parameter of graft viability. To determine whether bile production is a suitable biomarker that can be used to discriminate viable from non-viable livers we have studied functional performance as well as biochemical and his...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 101  شماره 

صفحات  -

تاریخ انتشار 2017